Admittance-Reshaping Method for LCL-Type Grid-Connected Converters Under Weak-Grid Conditions and Background Harmonic Disturbances

Large-scale integration of renewable energy sources and power-electronic equipment introduces substantial background harmonics into the grid and, at the same time, gives rise to weak-grid operating conditions with a low short-circuit ratio, thereby degrading the power quality and stability of grid-connected converters. This paper investigates a three-phase LCL-type grid-connected converter and establishes a dq-domain admittance model that incorporates the DC-voltage outer loop, the phase-locked loop (PLL), and grid-voltage feedforward. On the basis of admittance-reshaping theory, a method is proposed to suppress the influence of background harmonics and enhance system stability. First, the frequency coupling caused by the structural asymmetry of the PLL and the voltage outer loop is decoupled to reduce the harmonic components in the grid current. Then, based on the decoupled model, the grid-voltage feedforward path is compensated to eliminate the negative-damping region in the converter output admittance and thus improve system stability under weak-grid conditions. Finally, simulation and experimental results verify the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-06-18
DOI
https://doi.org/10.3390/en19122884
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Admittance-Reshaping Method for LCL-Type Grid-Connected Converters Under Weak-Grid Conditions and Background Harmonic Disturbances

Kaixuan Tang, Yi-Xiang Wang, Xin Tang, Zheng Zhou et al.
Energies
Microgrid Control and Optimization
article

Admittance-Reshaping Method for LCL-Type Grid-Connected Converters Under Weak-Grid Conditions and Background Harmonic Disturbances

Kaixuan Tang, Yi-Xiang Wang, Xin Tang, Zheng Zhou, Jianxi Jin
article en

Abstract

Large-scale integration of renewable energy sources and power-electronic equipment introduces substantial background harmonics into the grid and, at the same time, gives rise to weak-grid operating conditions with a low short-circuit ratio, thereby degrading the power quality and stability of grid-connected converters. This paper investigates a three-phase LCL-type grid-connected converter and establishes a dq-domain admittance model that incorporates the DC-voltage outer loop, the phase-locked loop (PLL), and grid-voltage feedforward. On the basis of admittance-reshaping theory, a method is proposed to suppress the influence of background harmonics and enhance system stability. First, the frequency coupling caused by the structural asymmetry of the PLL and the voltage outer loop is decoupled to reduce the harmonic components in the grid current. Then, based on the decoupled model, the grid-voltage feedforward path is compensated to eliminate the negative-damping region in the converter output admittance and thus improve system stability under weak-grid conditions. Finally, simulation and experimental results verify the effectiveness of the proposed method.

EnergiesVol. 19(12)
Changsha University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 7%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.