Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study

Objectives: To evaluate the diagnostic performance of automated vertebral trabecular Hounsfield unit (HU) measurements derived from routine fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) for identifying low bone density. Methods: This retrospective study included 131 consecutive women (mean age, 53.5 ± 9.6 years) undergoing health screening with FDG PET/CT and dual-energy X-ray absorptiometry (DXA) between January 2020 and December 2024. A deep learning-based model (TotalSegmentator) automatically segmented the lumbar vertebrae (L1–L4). HU-based metrics in trabecular regions were calculated, and their correlations with DXA-derived bone mineral density (BMD) were assessed. Diagnostic performance was evaluated using receiver operating characteristic analysis. A multivariable logistic regression model incorporating mean HU, age, and body mass index was developed and internally validated using bootstrap resampling. Results: According to WHO criteria, 47 of 131 participants (35.9%) had low bone density. Mean HU demonstrated strong diagnostic performance (area under the curve [95% confidence interval]: L1, 0.861 [0.800–0.923]; L2, 0.852 [0.788–0.915]; L3, 0.861 [0.800–0.921]; L4, 0.845 [0.781–0.909]). L1 mean HU provided the most balanced performance (sensitivity, 0.851; specificity, 0.750); L3 mean HU was slightly inferior. L1 mean HU was strongly correlated with BMD (r = 0.821, p < 0.001). In multivariable analysis, mean HU independently predicted low bone density (odds ratio: 0.949, p < 0.001). The model achieved an accuracy of 0.786 and demonstrated favorable calibration performance. Conclusions: The automated assessment of vertebral trabecular HU from routine FDG PET/CT provides a reliable and highly efficient method for screening low bone density without additional radiation exposure or cost.

Authors

Institutions

Publication Details

Journal
Tomography
Published
2026-06-17
DOI
https://doi.org/10.3390/tomography12060089
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study

Sung Hoon Oh, Do-Hoon Kim, Hyun-Kyeong Yuk
Tomography
Bone health and osteoporosis research
article

Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study

Sung Hoon Oh, Do-Hoon Kim, Hyun-Kyeong Yuk
article en

Abstract

Objectives: To evaluate the diagnostic performance of automated vertebral trabecular Hounsfield unit (HU) measurements derived from routine fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) for identifying low bone density. Methods: This retrospective study included 131 consecutive women (mean age, 53.5 ± 9.6 years) undergoing health screening with FDG PET/CT and dual-energy X-ray absorptiometry (DXA) between January 2020 and December 2024. A deep learning-based model (TotalSegmentator) automatically segmented the lumbar vertebrae (L1–L4). HU-based metrics in trabecular regions were calculated, and their correlations with DXA-derived bone mineral density (BMD) were assessed. Diagnostic performance was evaluated using receiver operating characteristic analysis. A multivariable logistic regression model incorporating mean HU, age, and body mass index was developed and internally validated using bootstrap resampling. Results: According to WHO criteria, 47 of 131 participants (35.9%) had low bone density. Mean HU demonstrated strong diagnostic performance (area under the curve [95% confidence interval]: L1, 0.861 [0.800–0.923]; L2, 0.852 [0.788–0.915]; L3, 0.861 [0.800–0.921]; L4, 0.845 [0.781–0.909]). L1 mean HU provided the most balanced performance (sensitivity, 0.851; specificity, 0.750); L3 mean HU was slightly inferior. L1 mean HU was strongly correlated with BMD (r = 0.821, p < 0.001). In multivariable analysis, mean HU independently predicted low bone density (odds ratio: 0.949, p < 0.001). The model achieved an accuracy of 0.786 and demonstrated favorable calibration performance. Conclusions: The automated assessment of vertebral trabecular HU from routine FDG PET/CT provides a reliable and highly efficient method for screening low bone density without additional radiation exposure or cost.

TomographyVol. 12(6)
Eulji University (KR), Daejeon Eulji Medical Center, Eulji University (KR)
Good health and well-being
Openalex Percentile: Top 7%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.