Pulse‐based photoplethysmography quality assessment improves wearable seizure detection performance

OBJECTIVE: Wearable photoplethysmography (PPG) is increasingly used for seizure detection due to its ability to unobtrusively estimate heart rate (HR). However, the vulnerability of PPG to body movements often leads to unreliable HR estimates, compromising accurate seizure detection. Although this limitation is well recognized, methods for rejecting artifactual HR measures-and their impact on seizure detection performance-have not yet been studied. METHODS: We sourced data from the PROMISE trial, a home-based study in children with refractory epilepsy that evaluated the performance of the NightWatch (NW) in detecting nocturnal motor seizures. We applied a novel pulse-based quality assessment (PQA) method that evaluates the quality of each individual PPG pulse and excludes compromised ones prior to HR estimation. We compared the performance of PQA with two alternatives: HR-based quality assessment (HRQA), rejecting extreme outliers in consecutive inter-beat intervals, and no quality assessment (noQA). We assessed the impact of PQA, HRQA, and noQA on seizure detection performance by applying HR increase thresholds from 30% to 80% relative to the baseline. A permutation test with bootstrapping was applied for all statistical comparisons. RESULTS: We analyzed 741 NW alarms, comprising 135 true seizures and 606 non-seizure events in 28 children (46% female; age: 9.1 ± 3.3 years). Averaged across all evaluated detection thresholds, both PQA and HRQA significantly improved seizure detection performance compared to noQA (p < 0.005). PQA led to mean increases of 0.248 in sensitivity, 0.025 in positive predictive value (PPV), and 0.082 in F1-score. HRQA showed mean increases of 0.081 in sensitivity, 0.040 in PPV, and 0.056 in F1-score. At clinically relevant sensitivity levels (0.8, 0.85, and 0.9), PQA showed a relative improvement over HRQA, with F1-scores increasing by 4%-15% and PPV by 5%-19%. SIGNIFICANCE: Implementing PPG quality assessment-particularly pulse-based-improves the performance of wearable HR-based seizure detection. PLAIN LANGUAGE SUMMARY: This study aimed to improve seizure detection in wearable devices by introducing a new method for assessing the quality of the heart rate (HR) data derived from a light sensor called photoplethysmography (PPG). By applying our method to data from children with epilepsy, we showed that discarding low-quality PPG data before HR estimation leads to better seizure detection, allowing more seizures to be correctly identified. This improvement is important because it enhances seizure detection performance through a software-only upgrade.

Authors

Institutions

Publication Details

Journal
Epilepsia Open
Published
2026-06-17
DOI
https://doi.org/10.1002/epi4.70242
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse‐based photoplethysmography quality assessment improves wearable seizure detection performance

Mohammad Shahbakhti, Roland D. Thijs, Anemoon T. Bosch, Xi Long et al.
Epilepsia Open
Non-Invasive Vital Sign Monitoring
article

Pulse‐based photoplethysmography quality assessment improves wearable seizure detection performance

Mohammad Shahbakhti, Roland D. Thijs, Anemoon T. Bosch, Xi Long, Johannes van Dijk
article en

Abstract

OBJECTIVE: Wearable photoplethysmography (PPG) is increasingly used for seizure detection due to its ability to unobtrusively estimate heart rate (HR). However, the vulnerability of PPG to body movements often leads to unreliable HR estimates, compromising accurate seizure detection. Although this limitation is well recognized, methods for rejecting artifactual HR measures-and their impact on seizure detection performance-have not yet been studied. METHODS: We sourced data from the PROMISE trial, a home-based study in children with refractory epilepsy that evaluated the performance of the NightWatch (NW) in detecting nocturnal motor seizures. We applied a novel pulse-based quality assessment (PQA) method that evaluates the quality of each individual PPG pulse and excludes compromised ones prior to HR estimation. We compared the performance of PQA with two alternatives: HR-based quality assessment (HRQA), rejecting extreme outliers in consecutive inter-beat intervals, and no quality assessment (noQA). We assessed the impact of PQA, HRQA, and noQA on seizure detection performance by applying HR increase thresholds from 30% to 80% relative to the baseline. A permutation test with bootstrapping was applied for all statistical comparisons. RESULTS: We analyzed 741 NW alarms, comprising 135 true seizures and 606 non-seizure events in 28 children (46% female; age: 9.1 ± 3.3 years). Averaged across all evaluated detection thresholds, both PQA and HRQA significantly improved seizure detection performance compared to noQA (p < 0.005). PQA led to mean increases of 0.248 in sensitivity, 0.025 in positive predictive value (PPV), and 0.082 in F1-score. HRQA showed mean increases of 0.081 in sensitivity, 0.040 in PPV, and 0.056 in F1-score. At clinically relevant sensitivity levels (0.8, 0.85, and 0.9), PQA showed a relative improvement over HRQA, with F1-scores increasing by 4%-15% and PPV by 5%-19%. SIGNIFICANCE: Implementing PPG quality assessment-particularly pulse-based-improves the performance of wearable HR-based seizure detection. PLAIN LANGUAGE SUMMARY: This study aimed to improve seizure detection in wearable devices by introducing a new method for assessing the quality of the heart rate (HR) data derived from a light sensor called photoplethysmography (PPG). By applying our method to data from children with epilepsy, we showed that discarding low-quality PPG data before HR estimation leads to better seizure detection, allowing more seizures to be correctly identified. This improvement is important because it enhances seizure detection performance through a software-only upgrade.

Epilepsia Open
Universität Ulm (DE), Leiden University Medical Center (NL), Kempenhaeghe (NL), National Hospital for Neurology and Neurosurgery (GB), Stichting Epilepsie Instellingen Nederland (NL), University College London (GB), Eindhoven University of Technology (NL)
Openalex Percentile: Top 12%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.