An in situ non-contact 3D microscopic measurement system for temporal bone anatomy based on stereo imaging

Accurate quantitative assessment of temporal bone microanatomy is essential for otologic research and surgical planning. However, existing measurement approaches, including manual tools, ex vivo microscopy, and high-resolution computed tomography, are limited by contact requirements, indirect measurement, insufficient spatial resolution, or the inability to provide efficient quantitative feedback under microscopic visualization. To address these limitations, this study developed an in situ, non-contact three-dimensional (3D) microscopic measurement system for temporal bone anatomy based on stereo imaging. The system integrates microscopic stereo calibration, deep learning-based disparity estimation, 3D reconstruction, and an interactive measurement workflow. Reconstruction accuracy was evaluated using a high-precision scanned LEGO model, while measurement accuracy was validated using a custom-designed 3D-printed module with known geometric dimensions. The feasibility of the system was further demonstrated through measurements of representative anatomical structures in four temporal bones from two fresh-frozen cadaver heads. The results showed that the root mean square error of 3D reconstruction was 0.05-0.13 mm. For geometric measurements, the average error was below 1.7%, with a maximum error below 4.0% across multiple metrics. The system enabled in situ, non-contact measurement of various anatomical parameters under microscopic conditions. These findings indicate that the proposed system provides accurate and reliable quantitative 3D measurement of temporal bone microstructures. As a technical prototype, it provides a practical tool for anatomical research and supports future development toward intraoperative, non-contact, in situ quantitative assessment in otomicrosurgery.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-17
DOI
https://doi.org/10.1038/s41598-026-56801-1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An in situ non-contact 3D microscopic measurement system for temporal bone anatomy based on stereo imaging

Yi Yuan, Bo Gao, Honglei Zhang, Dongyang Kang et al.
Scientific Reports
Optical measurement and interference techniques
article

An in situ non-contact 3D microscopic measurement system for temporal bone anatomy based on stereo imaging

Yi Yuan, Bo Gao, Honglei Zhang, Dongyang Kang, Ji Tang, Guojian Wang, Chaoyue Zhao, Hang Shao, Lihua Wu, Pu Dai, Wei Liu
article en

Abstract

Accurate quantitative assessment of temporal bone microanatomy is essential for otologic research and surgical planning. However, existing measurement approaches, including manual tools, ex vivo microscopy, and high-resolution computed tomography, are limited by contact requirements, indirect measurement, insufficient spatial resolution, or the inability to provide efficient quantitative feedback under microscopic visualization. To address these limitations, this study developed an in situ, non-contact three-dimensional (3D) microscopic measurement system for temporal bone anatomy based on stereo imaging. The system integrates microscopic stereo calibration, deep learning-based disparity estimation, 3D reconstruction, and an interactive measurement workflow. Reconstruction accuracy was evaluated using a high-precision scanned LEGO model, while measurement accuracy was validated using a custom-designed 3D-printed module with known geometric dimensions. The feasibility of the system was further demonstrated through measurements of representative anatomical structures in four temporal bones from two fresh-frozen cadaver heads. The results showed that the root mean square error of 3D reconstruction was 0.05-0.13 mm. For geometric measurements, the average error was below 1.7%, with a maximum error below 4.0% across multiple metrics. The system enabled in situ, non-contact measurement of various anatomical parameters under microscopic conditions. These findings indicate that the proposed system provides accurate and reliable quantitative 3D measurement of temporal bone microstructures. As a technical prototype, it provides a practical tool for anatomical research and supports future development toward intraoperative, non-contact, in situ quantitative assessment in otomicrosurgery.

Scientific Reports
Fujian Medical University (CN), Chinese PLA General Hospital (CN), National Clinical Research Center for Digestive Diseases (CN), Jiaxing University (CN), Air Force General Hospital PLA (CN), Fujian Provincial Hospital (CN), Tsinghua University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 6%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.