Repeatability of AI-quantified incidental findings on lung cancer screening CT scans in the NELSON trial

OBJECTIVES: Computed tomography (CT) scans for lung cancer screening provide the opportunity of quantifying incidental findings. We evaluated the repeatability of AI-based measurements of incidental findings using short-term repeat CT scan pairs. MATERIALS AND METHODS: AI-Rad Companion Chest CT software was applied to low-dose non-contrast CT scans from the NELSON lung cancer screening trial to measure aorta diameters, coronary artery calcium volume (CACV), vertebral height and radiodensity, and emphysema (low attenuation area percentage, LAA%). Categories (absent/present) of aortic dilatation and osteopenia, and severity (none/mild/moderate/severe) of CACV and emphysema were calculated. We included subjects who had a short-term repeat CT scan pair with a maximum interval of 120 days. We analyzed repeatability with absolute and relative differences, and agreement with the intraclass correlation coefficient (ICC) and Cohen's kappa. RESULTS: for CACV, 0.3 mm to 0.4 mm for vertebral height, and 7.6 HU for vertebral radiodensity. Median absolute difference was 0.8% for LAA%. Aorta diameters showed good (0.75 < ICC < 0.9) to excellent (ICC > 0.9) agreement. Agreement for the rest was excellent. Categorization Cohen's kappa between the first and second measurements was 0.68 for aortic dilatation, 0.63 for CACV, 0.84 for osteopenia, and 0.70 for emphysema. CONCLUSION: In a lung cancer screening cohort with short-term repeat CT, the repeatability and agreement of automated AI measurements of aortic diameters, coronary calcium, vertebral height and radiodensity, and emphysema was good to excellent. KEY POINTS: Question Can AI measurements of incidental findings beyond lung nodules be repeatably performed on pairs of lung cancer screening chest CT scans of the same subject? Findings The repeatability and agreement of AI-based measurements of aorta diameter, coronary calcium, vertebrae, and emphysema were generally excellent. Clinical relevance Measurement by radiologists of incidental findings on lung cancer screening chest CT scans imposes a high workload. AI algorithms allow for automatic measurement of incidental findings on lung cancer screening chest CT with high repeatability and agreement.

Authors

Institutions

Publication Details

Journal
European Radiology
Published
2026-06-17
DOI
https://doi.org/10.1007/s00330-026-12669-3
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeatability of AI-quantified incidental findings on lung cancer screening CT scans in the NELSON trial

G S Downward, R Vliegenthart, Ralph Stadhouders, Hester A. Gietema et al.
European Radiology
Lung Cancer Diagnosis and Treatment
article

Repeatability of AI-quantified incidental findings on lung cancer screening CT scans in the NELSON trial

G S Downward, R Vliegenthart, Ralph Stadhouders, Hester A. Gietema, Colin Jacobs, Firdaus A. A. Mohamed Hoesein, Roel C.H. Vermeulen, Jeroen van Rooij, Kristiaan Nackaerts, Robin Cornelissen, Marjolein A. Heuvelmans, Harry J.M. Groen, Edwin Bennink, Mathias Prokop, Walter De Wever, Lianne Trap, Thijs Bruins Slot, Félix Lades, Nils van der Velden, Pim A. de Jong, Danrong Zhong, Markus Sebald, Joachim G. Aerts, Geertruida H. de Bock, Stijn Bunk, Grigory Sidorenkov, C Schaefer-Prokop, Noa Antonissen, Niels Schurink
article en

Abstract

OBJECTIVES: Computed tomography (CT) scans for lung cancer screening provide the opportunity of quantifying incidental findings. We evaluated the repeatability of AI-based measurements of incidental findings using short-term repeat CT scan pairs. MATERIALS AND METHODS: AI-Rad Companion Chest CT software was applied to low-dose non-contrast CT scans from the NELSON lung cancer screening trial to measure aorta diameters, coronary artery calcium volume (CACV), vertebral height and radiodensity, and emphysema (low attenuation area percentage, LAA%). Categories (absent/present) of aortic dilatation and osteopenia, and severity (none/mild/moderate/severe) of CACV and emphysema were calculated. We included subjects who had a short-term repeat CT scan pair with a maximum interval of 120 days. We analyzed repeatability with absolute and relative differences, and agreement with the intraclass correlation coefficient (ICC) and Cohen's kappa. RESULTS: for CACV, 0.3 mm to 0.4 mm for vertebral height, and 7.6 HU for vertebral radiodensity. Median absolute difference was 0.8% for LAA%. Aorta diameters showed good (0.75 < ICC < 0.9) to excellent (ICC > 0.9) agreement. Agreement for the rest was excellent. Categorization Cohen's kappa between the first and second measurements was 0.68 for aortic dilatation, 0.63 for CACV, 0.84 for osteopenia, and 0.70 for emphysema. CONCLUSION: In a lung cancer screening cohort with short-term repeat CT, the repeatability and agreement of automated AI measurements of aortic diameters, coronary calcium, vertebral height and radiodensity, and emphysema was good to excellent. KEY POINTS: Question Can AI measurements of incidental findings beyond lung nodules be repeatably performed on pairs of lung cancer screening chest CT scans of the same subject? Findings The repeatability and agreement of AI-based measurements of aorta diameter, coronary calcium, vertebrae, and emphysema were generally excellent. Clinical relevance Measurement by radiologists of incidental findings on lung cancer screening chest CT scans imposes a high workload. AI algorithms allow for automatic measurement of incidental findings on lung cancer screening chest CT with high repeatability and agreement.

European Radiology
University Medical Center Groningen (NL), Radboud University Nijmegen (NL), University of Groningen (NL), Utrecht University (NL), Erasmus MC (NL), Radboud University Medical Center (NL), University Medical Center Utrecht (NL), Maastricht University (NL), Siemens Healthcare (United States) (US), Siemens Healthineers (Germany) (DE), Erasmus University Rotterdam (NL), KU Leuven (BE)
KWF Kankerbestrijding
Good health and well-being
Openalex Percentile: Top 8%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.