Exergy Efficiency Is a Key Performance Indicator to Rank Advanced Active Energy Technologies at the District Level

Supplying electricity, heat and cold is an essential part of the development of more sustainable city districts. Previous studies have illustrated interest in using the exergy efficiency concept to decompose the problem and rank the technology combinations for heating or cooling according to their overall efficiency. This methodology is extended herein to include network losses that depend on the temperature level and grid losses that play a role when comparing electricity supplied by the grid rather than by local cogeneration units. This extended method is then applied by considering two emerging technologies. The first is very-low-temperature district heating and cooling (DHC), directly supplying air-conditioning needs via simple heat exchangers, as well as heating needs via local heat pumps. It is part of what are called fifth-generation DHCs or “anergy networks” and based on water or, better, on CO2 heat-transfer fluid. The main features of the five generations of networks, as well as the average aggregate user needs, are summarized in pinch technology composites, but replacing the temperature axis with a heat exergy axis to graphically highlight exergy losses. The average aggregate heating and cooling needs of users result from the application of a geographic information system to a district in a real city. The second emerging technology considers hybrid SOFC–GT cogeneration units, with or without CO2 separation, supplying electricity to all network users, including decentralized heat pumps, while optimizing the recovery of waste heat. The full synergy between heat providers and users is highlighted, allowing districts without cooling towers or chimneys except at one energy balancing plant. Integration of the advanced SOFC–GT cogeneration unit considered herein into the same anergy network allows an increase in exergy efficiency from 13.6% to 21.3%, as compared with electricity being supplied entirely from the grid and produced with a similar natural gas fuel.

Authors

Institutions

Publication Details

Journal
Entropy
Published
2026-06-16
DOI
https://doi.org/10.3390/e28060693
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy Efficiency Is a Key Performance Indicator to Rank Advanced Active Energy Technologies at the District Level

Daniel Favrat
Entropy
Integrated Energy Systems Optimization
article

Exergy Efficiency Is a Key Performance Indicator to Rank Advanced Active Energy Technologies at the District Level

Daniel Favrat
article en

Abstract

Supplying electricity, heat and cold is an essential part of the development of more sustainable city districts. Previous studies have illustrated interest in using the exergy efficiency concept to decompose the problem and rank the technology combinations for heating or cooling according to their overall efficiency. This methodology is extended herein to include network losses that depend on the temperature level and grid losses that play a role when comparing electricity supplied by the grid rather than by local cogeneration units. This extended method is then applied by considering two emerging technologies. The first is very-low-temperature district heating and cooling (DHC), directly supplying air-conditioning needs via simple heat exchangers, as well as heating needs via local heat pumps. It is part of what are called fifth-generation DHCs or “anergy networks” and based on water or, better, on CO2 heat-transfer fluid. The main features of the five generations of networks, as well as the average aggregate user needs, are summarized in pinch technology composites, but replacing the temperature axis with a heat exergy axis to graphically highlight exergy losses. The average aggregate heating and cooling needs of users result from the application of a geographic information system to a district in a real city. The second emerging technology considers hybrid SOFC–GT cogeneration units, with or without CO2 separation, supplying electricity to all network users, including decentralized heat pumps, while optimizing the recovery of waste heat. The full synergy between heat providers and users is highlighted, allowing districts without cooling towers or chimneys except at one energy balancing plant. Integration of the advanced SOFC–GT cogeneration unit considered herein into the same anergy network allows an increase in exergy efficiency from 13.6% to 21.3%, as compared with electricity being supplied entirely from the grid and produced with a similar natural gas fuel.

EntropyVol. 28(6)
École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 9%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.