Lean and Green Hand Surgery: Evaluating the Sterility of Stored Corticosteroid Injection Preparations Using Next-Generation Sequencing

BACKGROUND: Corticosteroid injections are commonly performed in hand surgery and are often prepared in advance to improve efficiency. Despite aseptic preparation, unused syringes are routinely discarded due to concerns about microbiologic contamination, resulting in substantial avoidable waste. We conducted a controlled laboratory study simulating outpatient injection workflows to assess the sterility of stored corticosteroid-lidocaine injections using next-generation sequencing (NGS). METHODS: Sterile corticosteroid-lidocaine injections were prepared under aseptic conditions using sterile 3 mL Luer-lock syringes, 0.5 mL of 1% lidocaine, and 3 mg of triamcinolone acetonide (20 mg/mL), drawn with an 18-gauge needle and capped with a sterile 25-gauge needle. Syringes were labeled and stored at room temperature in a closed cabinet away from light and temperature fluctuation. The primary endpoint was the detection of bacterial DNA by NGS on either the 25-gauge needle or the fluid in the syringe. Samples were analyzed at 1 day, 3 days, 1 week, and 2 weeks postpreparation. RESULTS: species. All positive controls from the 1-day, 3-day, and 1-week groups demonstrated polymicrobial contamination. CONCLUSIONS: Predrawn corticosteroid injections prepared under aseptic conditions demonstrated a low contamination rate over 2 weeks. These findings support extending injection use beyond same-day administration and provide an opportunity to reduce waste, lower costs, and advance sustainability in hand surgery.

Authors

Institutions

Publication Details

Journal
Hand
Published
2026-06-17
DOI
https://doi.org/10.1177/15589447261453554
Primary Topic
Infection Control in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lean and Green Hand Surgery: Evaluating the Sterility of Stored Corticosteroid Injection Preparations Using Next-Generation Sequencing

Erin Hale, Bijan Dehghani, Andrew D. Sobel, Harmon Singh Khela et al.
Hand
Infection Control in Healthcare
article

Lean and Green Hand Surgery: Evaluating the Sterility of Stored Corticosteroid Injection Preparations Using Next-Generation Sequencing

Erin Hale, Bijan Dehghani, Andrew D. Sobel, Harmon Singh Khela, Ana Sofia Rive, Kurt Mohty
article en

Abstract

BACKGROUND: Corticosteroid injections are commonly performed in hand surgery and are often prepared in advance to improve efficiency. Despite aseptic preparation, unused syringes are routinely discarded due to concerns about microbiologic contamination, resulting in substantial avoidable waste. We conducted a controlled laboratory study simulating outpatient injection workflows to assess the sterility of stored corticosteroid-lidocaine injections using next-generation sequencing (NGS). METHODS: Sterile corticosteroid-lidocaine injections were prepared under aseptic conditions using sterile 3 mL Luer-lock syringes, 0.5 mL of 1% lidocaine, and 3 mg of triamcinolone acetonide (20 mg/mL), drawn with an 18-gauge needle and capped with a sterile 25-gauge needle. Syringes were labeled and stored at room temperature in a closed cabinet away from light and temperature fluctuation. The primary endpoint was the detection of bacterial DNA by NGS on either the 25-gauge needle or the fluid in the syringe. Samples were analyzed at 1 day, 3 days, 1 week, and 2 weeks postpreparation. RESULTS: species. All positive controls from the 1-day, 3-day, and 1-week groups demonstrated polymicrobial contamination. CONCLUSIONS: Predrawn corticosteroid injections prepared under aseptic conditions demonstrated a low contamination rate over 2 weeks. These findings support extending injection use beyond same-day administration and provide an opportunity to reduce waste, lower costs, and advance sustainability in hand surgery.

Hand
University of Connecticut (US), University of Pennsylvania (US), Philadelphia University (US)
Responsible consumption and production
Openalex Percentile: Top 8%
Infection Control in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.