Three-Dimensional Seepage Response and Safety Assessment of a High Concrete-Face Rockfill Dam Under Joint Waterstop Failure Scenarios

To investigate the three-dimensional seepage response and safety implications of high concrete-face rockfill dams (CFRDs) under waterstop failure scenarios, this study establishes a refined three-dimensional finite element model for a high CFRD at the JD Hydropower Station using COMSOL (version 6.1) Multiphysics. A comparative analysis is conducted for six representative scenarios, including peripheral joint failure, single vertical joint failure, overall vertical joint failure, and combined failures. The seepage safety assessment is based on the phreatic surface, seepage discharge, hydraulic gradients in key zones, and left- and right-bank abutment bypass seepage. The results show that waterstop failure significantly changes the seepage field, phreatic surface, leakage discharge, and hydraulic gradients. Among the six scenarios, S5, representing overall vertical joint failure with an aperture of 0.5 mm for each of the 41 vertical joints, produces the most unfavorable leakage response, with the total seepage discharge reaching 3010.46 L/s and the water level behind the face slab reaching 3888.23 m. In contrast, peripheral joint failure mainly induces local hydraulic-gradient concentration in the special cushion zone. Under S1, the maximum hydraulic gradient in the special cushion zone reaches 2.72, exceeding the allowable value of 0.72. The results also reveal asymmetric bypass seepage around the dam abutments, with the right-bank foundation leakage being 90.4–137.7% higher than that on the left bank. These findings clarify the distinct seepage risk mechanisms of different waterstop failures and provide support for waterstop design, construction quality control, targeted monitoring, and operation-stage safety assessment of high CFRDs.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-06-17
DOI
https://doi.org/10.3390/w18121488
Primary Topic
Dam Engineering and Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Dimensional Seepage Response and Safety Assessment of a High Concrete-Face Rockfill Dam Under Joint Waterstop Failure Scenarios

Yan Sun, Yaohong Yang, Jialin Chen, Xinqi Zhao et al.
Water
Dam Engineering and Safety
article

Three-Dimensional Seepage Response and Safety Assessment of a High Concrete-Face Rockfill Dam Under Joint Waterstop Failure Scenarios

Yan Sun, Yaohong Yang, Jialin Chen, Xinqi Zhao, Fengming Zhou, Shoukai Chen, Yibing Song
article en

Abstract

To investigate the three-dimensional seepage response and safety implications of high concrete-face rockfill dams (CFRDs) under waterstop failure scenarios, this study establishes a refined three-dimensional finite element model for a high CFRD at the JD Hydropower Station using COMSOL (version 6.1) Multiphysics. A comparative analysis is conducted for six representative scenarios, including peripheral joint failure, single vertical joint failure, overall vertical joint failure, and combined failures. The seepage safety assessment is based on the phreatic surface, seepage discharge, hydraulic gradients in key zones, and left- and right-bank abutment bypass seepage. The results show that waterstop failure significantly changes the seepage field, phreatic surface, leakage discharge, and hydraulic gradients. Among the six scenarios, S5, representing overall vertical joint failure with an aperture of 0.5 mm for each of the 41 vertical joints, produces the most unfavorable leakage response, with the total seepage discharge reaching 3010.46 L/s and the water level behind the face slab reaching 3888.23 m. In contrast, peripheral joint failure mainly induces local hydraulic-gradient concentration in the special cushion zone. Under S1, the maximum hydraulic gradient in the special cushion zone reaches 2.72, exceeding the allowable value of 0.72. The results also reveal asymmetric bypass seepage around the dam abutments, with the right-bank foundation leakage being 90.4–137.7% higher than that on the left bank. These findings clarify the distinct seepage risk mechanisms of different waterstop failures and provide support for waterstop design, construction quality control, targeted monitoring, and operation-stage safety assessment of high CFRDs.

WaterVol. 18(12)
North China University of Water Resources and Electric Power (CN), Zhengzhou University (CN), Nanyang Institute of Technology (CN)
Natural Science Foundation of Henan Province, Henan Provincial Science and Technology Research Project
Sustainable cities and communities
Openalex Percentile: Top 11%
Dam Engineering and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.