The Charging-Up Phenomenon in Gas Electron Multiplier Detector

Gas Electron Multiplier (GEM) detectors have become an indispensable component of modern tracking systems. The heart of a GEM detector is a thin polyimide foil (∼50 µm) clad with copper (∼5 µm) on both sides and containing an array of regularly spaced holes (typically diameter of ∼70 µm and pitch of ∼140 µm) fabricated using photolithographic techniques. The presence of the dielectric substrate (polyimide) within the amplification region introduces a time dependent response when the detector is exposed to external irradiation, a phenomenon commonly referred to as the charging-up effect. This effect arises from the accumulation of charge on the insulating polyimide surfaces, leading to a gradual modification of the local electric field configuration inside the GEM holes and, consequently, a variation in the detector gain over time. The charging-up behaviour has been systematically investigated for triple GEM chamber prototypes using an Fe-55 radioactive source (5.9 keV X-rays) with an activity of ∼20 mCi. The characteristic charging-up time constant has been extracted, and its dependence on detector gain and irradiation rate has been examined. In addition, the uniformity of detector performance in terms of count rate, gain, and energy resolution has been studied both before and after the charging-up process. In this review article, the experimental setup, data acquisition methodology, and analysis procedures developed and carried out by our group are summarised. The key findings reported by other groups, relevant Monte Carlo simulation efforts, and future outlook for the charging-up investigation on GEM based detectors are also discussed in this article. The investigations and their outcomes reviewed here provide valuable insight into the charging-up dynamics of GEM detectors and their dependence on operational parameters.

Authors

Institutions

Publication Details

Journal
Particles
Published
2026-06-17
DOI
https://doi.org/10.3390/particles9020065
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Charging-Up Phenomenon in Gas Electron Multiplier Detector

S. Das, S. Biswas, S. Chatterjee
Particles
Particle Detector Development and Performance
article

The Charging-Up Phenomenon in Gas Electron Multiplier Detector

S. Das, S. Biswas, S. Chatterjee
article en

Abstract

Gas Electron Multiplier (GEM) detectors have become an indispensable component of modern tracking systems. The heart of a GEM detector is a thin polyimide foil (∼50 µm) clad with copper (∼5 µm) on both sides and containing an array of regularly spaced holes (typically diameter of ∼70 µm and pitch of ∼140 µm) fabricated using photolithographic techniques. The presence of the dielectric substrate (polyimide) within the amplification region introduces a time dependent response when the detector is exposed to external irradiation, a phenomenon commonly referred to as the charging-up effect. This effect arises from the accumulation of charge on the insulating polyimide surfaces, leading to a gradual modification of the local electric field configuration inside the GEM holes and, consequently, a variation in the detector gain over time. The charging-up behaviour has been systematically investigated for triple GEM chamber prototypes using an Fe-55 radioactive source (5.9 keV X-rays) with an activity of ∼20 mCi. The characteristic charging-up time constant has been extracted, and its dependence on detector gain and irradiation rate has been examined. In addition, the uniformity of detector performance in terms of count rate, gain, and energy resolution has been studied both before and after the charging-up process. In this review article, the experimental setup, data acquisition methodology, and analysis procedures developed and carried out by our group are summarised. The key findings reported by other groups, relevant Monte Carlo simulation efforts, and future outlook for the charging-up investigation on GEM based detectors are also discussed in this article. The investigations and their outcomes reviewed here provide valuable insight into the charging-up dynamics of GEM detectors and their dependence on operational parameters.

ParticlesVol. 9(2)
Bose Institute (IN), University of Massachusetts Amherst (US)
CERN, Department of Science and Technology, Ministry of Science and Technology, India, Bose Institute, Science and Engineering Research Board
Affordable and clean energy
Openalex Percentile: Top 7%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.