Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting

Standardized preanalytical sample handling is a cornerstone of reliable molecular analytics, particularly where subtle multimolecular differences can drive biological interpretation. In different clinical studies, blood-based samples are often processed using varying workflows, and the influence of individual technical parameters remains poorly quantified. In particular, preanalytical differences can limit study comparability and complicate the robust evaluation of the approach for different applications and specific medical questions. Here, we systematically investigate the effects of major preanalytical variables on infrared molecular fingerprinting (IMF) of blood serum and plasma, performed via Fourier transform infrared (FTIR) spectroscopy. We examine the impacts of venous blood draw tube types, tube fill volumes, delay times prior to centrifugation, centrifugation conditions, freezing and thawing procedures, and delay times between final sample preparation and infrared spectroscopy. We found that the type of blood collection tube, the fill volume of the tube, a delay of more than 4 h before centrifugation, more than two freeze-thaw cycles, and delays prior to measurement can result in systematic changes in infrared fingerprints that are detectable through multivariate analysis and machine learning. Importantly, for most conditions, the magnitude of parameter-related spectral variation remains smaller than the intrinsic biological variability across individuals, supporting the feasibility of IMF for realistic clinical settings. The presented results provide actionable guidance and a basis for harmonizing preanalytical workflows, reducing preanalytical confounding in IMF-based biofluid analysis, and improving cross-study comparability, with relevance that may generalize to other molecular profiling technologies, clinical studies, and biobanking.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-06-17
DOI
https://doi.org/10.1021/acs.analchem.6c01358
Primary Topic
Forensic Fingerprint Detection Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting

Mihaela Žigman, Katharina Dietmann, Frank Fleischmann, Tarek Eissa et al.
Analytical Chemistry
Forensic Fingerprint Detection Methods
article

Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting

Mihaela Žigman, Katharina Dietmann, Frank Fleischmann, Tarek Eissa, Jacqueline Aschauer, Guanting Guo
article en

Abstract

Standardized preanalytical sample handling is a cornerstone of reliable molecular analytics, particularly where subtle multimolecular differences can drive biological interpretation. In different clinical studies, blood-based samples are often processed using varying workflows, and the influence of individual technical parameters remains poorly quantified. In particular, preanalytical differences can limit study comparability and complicate the robust evaluation of the approach for different applications and specific medical questions. Here, we systematically investigate the effects of major preanalytical variables on infrared molecular fingerprinting (IMF) of blood serum and plasma, performed via Fourier transform infrared (FTIR) spectroscopy. We examine the impacts of venous blood draw tube types, tube fill volumes, delay times prior to centrifugation, centrifugation conditions, freezing and thawing procedures, and delay times between final sample preparation and infrared spectroscopy. We found that the type of blood collection tube, the fill volume of the tube, a delay of more than 4 h before centrifugation, more than two freeze-thaw cycles, and delays prior to measurement can result in systematic changes in infrared fingerprints that are detectable through multivariate analysis and machine learning. Importantly, for most conditions, the magnitude of parameter-related spectral variation remains smaller than the intrinsic biological variability across individuals, supporting the feasibility of IMF for realistic clinical settings. The presented results provide actionable guidance and a basis for harmonizing preanalytical workflows, reducing preanalytical confounding in IMF-based biofluid analysis, and improving cross-study comparability, with relevance that may generalize to other molecular profiling technologies, clinical studies, and biobanking.

Analytical Chemistry
Institute of Experimental Physics of the Slovak Academy of Sciences (SK), Max Planck Institute of Quantum Optics (DE), University of Medicine 2 Yangon (MM), Joint Attosecond Science Laboratory (CA), Technical University of Munich (DE), Ludwig-Maximilians-Universität München (DE)
Ludwig-Maximilians-Universität München
Openalex Percentile: Top 5%
Forensic Fingerprint Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.