Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors

Intermittent faults in electrical connectors refer to cases in which contact resistance exceeds a specified threshold for microseconds or less, causing transient power or signal interruptions. Accurate detection and quantitative recording of these events are important for connector reliability evaluation. In this work, an eight-channel monitoring system with nanosecond resolution for intermittent faults in electrical connectors is developed, enabling quantitative recording of intermittent events together with dynamic contact resistance (DCR) waveform acquisition. Two-stage programmable amplification is used for DCR measurement, while threshold comparison and FPGA-abased quadrature multiphase oversampling are combined to capture intermittent events. The system supports DCR measurement over 1 mΩ–10,000 mΩ with a maximum relative error of 0.41%, and provides 1.25 ns equivalent time resolution for intermittent event monitoring, with an expanded uncertainty of 0.28 ns–0.54 ns over 20 ns–10 μs. Vibration tests on high-speed connectors further demonstrate that the system captures real intermittent events under mechanical excitation and measures their durations with a maximum relative error of 0.66% relative to oscilloscope results.

Authors

Institutions

Publication Details

Journal
Inventions
Published
2026-06-17
DOI
https://doi.org/10.3390/inventions11030064
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors

Yinnan Zhang, Wanbin Ren, Yuchen Liao, Chao Zhang et al.
Inventions
Electrical Fault Detection and Protection
article

Multi-Channel Monitoring System with Nanosecond Resolution for Intermittent Faults in Electrical Connectors

Yinnan Zhang, Wanbin Ren, Yuchen Liao, Chao Zhang, Yuan Meng
article en

Abstract

Intermittent faults in electrical connectors refer to cases in which contact resistance exceeds a specified threshold for microseconds or less, causing transient power or signal interruptions. Accurate detection and quantitative recording of these events are important for connector reliability evaluation. In this work, an eight-channel monitoring system with nanosecond resolution for intermittent faults in electrical connectors is developed, enabling quantitative recording of intermittent events together with dynamic contact resistance (DCR) waveform acquisition. Two-stage programmable amplification is used for DCR measurement, while threshold comparison and FPGA-abased quadrature multiphase oversampling are combined to capture intermittent events. The system supports DCR measurement over 1 mΩ–10,000 mΩ with a maximum relative error of 0.41%, and provides 1.25 ns equivalent time resolution for intermittent event monitoring, with an expanded uncertainty of 0.28 ns–0.54 ns over 20 ns–10 μs. Vibration tests on high-speed connectors further demonstrate that the system captures real intermittent events under mechanical excitation and measures their durations with a maximum relative error of 0.66% relative to oscilloscope results.

InventionsVol. 11(3)
Harbin Institute of Technology (CN), Chinese Academy of Civil Aviation Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 11%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.