Transesophageal Echocardiography Was Useful in Determining the Treatment Plan for Moderate Aortic Stenosis-Like Findings Associated With High Left Ventricular Output Immediately Following Biological Valve Replacement: A Case Report

An elevated transvalvular pressure gradient and accelerated blood flow immediately following aortic valve replacement (AVR) is occasionally observed. It requires careful differentiation between structural factors, such as prosthetic valve dysfunction or patient-prosthetic mismatch (PPM), and non-structural factors, including high left ventricular output. A 73-year-old woman presenting with severe aortic regurgitation underwent AVR with a 25 mm stented bioprosthetic valve and coronary artery bypass grafting. After weaning from cardiopulmonary bypass (CPB) under catecholamine support, intraoperative transesophageal echocardiography (TEE) revealed findings corresponding to moderate aortic stenosis (AS), with a maximum blood flow velocity of 3.4 m/s and a mean pressure gradient of 23 mmHg. However, further TEE evaluation demonstrated a normal effective orifice area index (EOAI) of 1.24 cm²/m² and a short blood flow acceleration time (AT) of 42 ms. Consequently, prosthetic valve dysfunction and PPM were ruled out, and these findings were attributed to a hyperdynamic state with high left ventricular output. Reoperation was successfully avoided. A follow-up transthoracic echocardiogram (TTE) on postoperative day 4 confirmed normal valve mobility without any signs of stenosis, and the patient was discharged without complications. TEE played a crucial role in accurately identifying a high left ventricular output state masquerading as moderate prosthetic valve stenosis immediately following surgery, thereby preventing unnecessary surgical reintervention.

Authors

Publication Details

Journal
Cureus
Published
2026-06-17
DOI
https://doi.org/10.7759/cureus.111049
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transesophageal Echocardiography Was Useful in Determining the Treatment Plan for Moderate Aortic Stenosis-Like Findings Associated With High Left Ventricular Output Immediately Following Biological Valve Replacement: A Case Report

Takumi Yamamoto, Keisuke Sumii
Cureus
Cardiac Valve Diseases and Treatments
article

Transesophageal Echocardiography Was Useful in Determining the Treatment Plan for Moderate Aortic Stenosis-Like Findings Associated With High Left Ventricular Output Immediately Following Biological Valve Replacement: A Case Report

Takumi Yamamoto, Keisuke Sumii
article en

Abstract

An elevated transvalvular pressure gradient and accelerated blood flow immediately following aortic valve replacement (AVR) is occasionally observed. It requires careful differentiation between structural factors, such as prosthetic valve dysfunction or patient-prosthetic mismatch (PPM), and non-structural factors, including high left ventricular output. A 73-year-old woman presenting with severe aortic regurgitation underwent AVR with a 25 mm stented bioprosthetic valve and coronary artery bypass grafting. After weaning from cardiopulmonary bypass (CPB) under catecholamine support, intraoperative transesophageal echocardiography (TEE) revealed findings corresponding to moderate aortic stenosis (AS), with a maximum blood flow velocity of 3.4 m/s and a mean pressure gradient of 23 mmHg. However, further TEE evaluation demonstrated a normal effective orifice area index (EOAI) of 1.24 cm²/m² and a short blood flow acceleration time (AT) of 42 ms. Consequently, prosthetic valve dysfunction and PPM were ruled out, and these findings were attributed to a hyperdynamic state with high left ventricular output. Reoperation was successfully avoided. A follow-up transthoracic echocardiogram (TTE) on postoperative day 4 confirmed normal valve mobility without any signs of stenosis, and the patient was discharged without complications. TEE played a crucial role in accurately identifying a high left ventricular output state masquerading as moderate prosthetic valve stenosis immediately following surgery, thereby preventing unnecessary surgical reintervention.

Cureus
Good health and well-being
Openalex Percentile: Top 8%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.