Microwave-Assisted N,S Co-Doped Reduced Graphene Oxide for Eco-Friendly Environmental Monitoring of Nitrobenzene

A nitrogen/sulfur co-doped reduced graphene oxide (N,S-RGO) material was rationally prepared via a modified Hummers method followed by microwave-assisted reduction. The resulting material was uniformly deposited onto a glassy carbon electrode (GCE) to fabricate an electrochemical sensor for nitrobenzene (NB) detection. The prepared N,S-RGO material was characterized in detail using Fourier-transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy, confirming the successful incorporation of heteroatoms. Furthermore, electrochemical studies, including cyclic voltammetry (CV) and linear sweep voltammetry (LSV), revealed the enhanced electrical conductivity of the material. The fabricated N,S-RGO/GCE sensor exhibited remarkable electroanalytical performance, achieving a low detection limit (LOD) of 7 nM within a linear concentration range of 0.05 to 147 µM. The enhanced sensing performance is attributed to the synergistic effect of nitrogen and sulfur doping, which improves electron transfer kinetics and abundant active sites for NB reduction. Furthermore, the sensor demonstrated outstanding selectivity toward NB in the presence of common interfering substances. Its practical applicability was confirmed through the successful detection of NB in environmental water samples, yielding convincing recovery rates. These results highlight the potential of the N,S-RGO/GCE platform as an efficient and reliable electrochemical sensor for environmental monitoring of NB contamination.

Authors

Institutions

Publication Details

Journal
C – Journal of Carbon Research
Published
2026-06-17
DOI
https://doi.org/10.3390/c12020052
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microwave-Assisted N,S Co-Doped Reduced Graphene Oxide for Eco-Friendly Environmental Monitoring of Nitrobenzene

Rasu Ramachandran, Tharini Jeyapragasam, Vinitha Mariyappan, M. Kandasamy et al.
C – Journal of Carbon Research
Electrochemical sensors and biosensors
article

Microwave-Assisted N,S Co-Doped Reduced Graphene Oxide for Eco-Friendly Environmental Monitoring of Nitrobenzene

Rasu Ramachandran, Tharini Jeyapragasam, Vinitha Mariyappan, M. Kandasamy, Prathingara Subramanian
article en

Abstract

A nitrogen/sulfur co-doped reduced graphene oxide (N,S-RGO) material was rationally prepared via a modified Hummers method followed by microwave-assisted reduction. The resulting material was uniformly deposited onto a glassy carbon electrode (GCE) to fabricate an electrochemical sensor for nitrobenzene (NB) detection. The prepared N,S-RGO material was characterized in detail using Fourier-transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy, confirming the successful incorporation of heteroatoms. Furthermore, electrochemical studies, including cyclic voltammetry (CV) and linear sweep voltammetry (LSV), revealed the enhanced electrical conductivity of the material. The fabricated N,S-RGO/GCE sensor exhibited remarkable electroanalytical performance, achieving a low detection limit (LOD) of 7 nM within a linear concentration range of 0.05 to 147 µM. The enhanced sensing performance is attributed to the synergistic effect of nitrogen and sulfur doping, which improves electron transfer kinetics and abundant active sites for NB reduction. Furthermore, the sensor demonstrated outstanding selectivity toward NB in the presence of common interfering substances. Its practical applicability was confirmed through the successful detection of NB in environmental water samples, yielding convincing recovery rates. These results highlight the potential of the N,S-RGO/GCE platform as an efficient and reliable electrochemical sensor for environmental monitoring of NB contamination.

C – Journal of Carbon ResearchVol. 12(2)
Madurai Kamaraj University (IN), National Chung Cheng University (TW), Ramakrishna Mission Vidyamandira (IN), University of Malaya (MY), University of Kuala Lumpur (MY)
Ministry of Education, India, King Khalid University
Life in Land
Openalex Percentile: Top 11%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.