The correlation between nursing workload and abnormal 24-h ambulatory blood pressure profiles in clinical nurses: a cross-sectional study

OBJECTIVE: To analyze 24-h ambulatory blood pressure profiles among clinical nurses and investigate their correlation with nursing workload. METHODS: This study enrolled 312 clinical nurses from a tertiary hospital in China between June 2024 and June 2025. All participants underwent 24-h ambulatory blood pressure monitoring. Latent profile analysis identified blood pressure profiles. Binary logistic regression identified workload indicators associated with abnormal profiles, and restricted cubic spline models assessed dose-response relationships. RESULTS: Four profiles were identified: the low ambulatory SBP dipper group (SBP<111 mmHg, dipper≥49%), the high ambulatory SBP rhythm variability group (SBP≥111 mmHg, abnormal circadian rhythm≥54%), the low ambulatory DBP dipper group (DBP<72 mmHg, dipper≥46%), and the high ambulatory DBP rhythm variability group (DBP≥72 mmHg, abnormal circadian rhythm≥61%). An increased number of patients admitted or transferred in was associated with abnormal SBP profiles [odds ratio (OR) 1.496, 95% confidence interval (95% CI) 1.069-2.094]. An increased total number of patients assigned was associated with abnormal DBP profiles (OR 1.228, 95% CI 1.014-1.488), whereas a higher number of patients with level II or below care needs was protective (OR 0.777, 95% CI 0.645-0.937). All associations were linear and varied across subgroups, with broader patterns observed in the high-variability groups. CONCLUSION: Abnormal blood pressure profiles in clinical nurses were characterized by elevated 24-h blood pressure (median 117.0/80.5 mmHg) and a high proportion of abnormal circadian rhythms (54.2% for SBP and 61.4% for DBP). Linear dose-response relationships exist between specific nursing workload and the risk of abnormal profiles.

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2026-06-17
DOI
https://doi.org/10.1097/hjh.0000000000004356
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The correlation between nursing workload and abnormal 24-h ambulatory blood pressure profiles in clinical nurses: a cross-sectional study

Suzhi Zhang, Yaping Wang, Ni Chen, Wenjia Liu et al.
Journal of Hypertension
Blood Pressure and Hypertension Studies
article

The correlation between nursing workload and abnormal 24-h ambulatory blood pressure profiles in clinical nurses: a cross-sectional study

Suzhi Zhang, Yaping Wang, Ni Chen, Wenjia Liu, Xiaolin Zhang, Yufang Zhu, Jie Liu, Bin Zhao, Huiling Liu
article en

Abstract

OBJECTIVE: To analyze 24-h ambulatory blood pressure profiles among clinical nurses and investigate their correlation with nursing workload. METHODS: This study enrolled 312 clinical nurses from a tertiary hospital in China between June 2024 and June 2025. All participants underwent 24-h ambulatory blood pressure monitoring. Latent profile analysis identified blood pressure profiles. Binary logistic regression identified workload indicators associated with abnormal profiles, and restricted cubic spline models assessed dose-response relationships. RESULTS: Four profiles were identified: the low ambulatory SBP dipper group (SBP<111 mmHg, dipper≥49%), the high ambulatory SBP rhythm variability group (SBP≥111 mmHg, abnormal circadian rhythm≥54%), the low ambulatory DBP dipper group (DBP<72 mmHg, dipper≥46%), and the high ambulatory DBP rhythm variability group (DBP≥72 mmHg, abnormal circadian rhythm≥61%). An increased number of patients admitted or transferred in was associated with abnormal SBP profiles [odds ratio (OR) 1.496, 95% confidence interval (95% CI) 1.069-2.094]. An increased total number of patients assigned was associated with abnormal DBP profiles (OR 1.228, 95% CI 1.014-1.488), whereas a higher number of patients with level II or below care needs was protective (OR 0.777, 95% CI 0.645-0.937). All associations were linear and varied across subgroups, with broader patterns observed in the high-variability groups. CONCLUSION: Abnormal blood pressure profiles in clinical nurses were characterized by elevated 24-h blood pressure (median 117.0/80.5 mmHg) and a high proportion of abnormal circadian rhythms (54.2% for SBP and 61.4% for DBP). Linear dose-response relationships exist between specific nursing workload and the risk of abnormal profiles.

Journal of Hypertension
Hebei Medical University (CN), Second Hospital of Hebei Medical University (CN), Office of Basic Energy Sciences (US)
Openalex Percentile: Top 8%
Blood Pressure and Hypertension Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.