Diagnostic performance of multiple artificial intelligence (AI) algorithms for diabetic retinopathy screening in primary care: Evidence from real-world settings in India

Purpose: The diagnostic performance of artificial intelligence (AI) in real-world settings remains uncertain, particularly across different fundus camera systems. This study evaluates the diagnostic accuracy of three AI algorithms for diabetic retinopathy (DR) detection using two nonmydriatic fundus cameras, assessing image gradability and DR severity. Methods: A prospective diagnostic accuracy study was conducted at a primary health center, Khijrabad, Punjab, India (March–July 2021). The study evaluated three commercially available artificial intelligence algorithms for DR detection using two nonmydriatic fundus cameras. Participants underwent two-field, nonmydriatic fundus imaging with both cameras. Image quality and DR presence were independently assessed by masked human graders, including optometrists and a retina specialist. Diagnostic performance was measured using sensitivity, specificity, and positive and negative predictive values. Results: A total of 272 images from 136 participants (mean age 67.7 years; 62% female) were analyzed. Human graders classified more than 97% of images as gradable, with DR detected in 47% of the images. AI-1 demonstrated the highest sensitivity (Forus: 97.5% (0.956–0.994); Intuvision: 81.7% (0.768–0.867)) but comparatively low specificity: 62.7% (58.6–66.8) and 53.8% (0.474–0.602). AI-2 displayed a balanced performance (sensitivity 80.0% and 77.0%; specificity 95.7% and 92.0%). AI-3 had a moderate sensitivity (73–80%) with the specificity ranging from 82% to 86%. Conclusion: AI performance varied across camera platforms, highlighting the need for context-specific validation to ensure safe integration into primary care and guide DR screening guidelines.

Authors

Institutions

Publication Details

Journal
Indian Journal of Ophthalmology
Published
2026-06-17
DOI
https://doi.org/10.4103/ijo.ijo_2774_25
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic performance of multiple artificial intelligence (AI) algorithms for diabetic retinopathy screening in primary care: Evidence from real-world settings in India

L Vale, Verma Pk, Mona Duggal, Geeta Menon et al.
Indian Journal of Ophthalmology
Retinal Imaging and Analysis
article

Diagnostic performance of multiple artificial intelligence (AI) algorithms for diabetic retinopathy screening in primary care: Evidence from real-world settings in India

L Vale, Verma Pk, Mona Duggal, Geeta Menon, Lakshay Kumar, Mitesh Yadav, V Gupta, Gagandeep Kaur, Anshul Chauhan, Piyasena Mapa Prabhath, Gursimran Rana
article en

Abstract

Purpose: The diagnostic performance of artificial intelligence (AI) in real-world settings remains uncertain, particularly across different fundus camera systems. This study evaluates the diagnostic accuracy of three AI algorithms for diabetic retinopathy (DR) detection using two nonmydriatic fundus cameras, assessing image gradability and DR severity. Methods: A prospective diagnostic accuracy study was conducted at a primary health center, Khijrabad, Punjab, India (March–July 2021). The study evaluated three commercially available artificial intelligence algorithms for DR detection using two nonmydriatic fundus cameras. Participants underwent two-field, nonmydriatic fundus imaging with both cameras. Image quality and DR presence were independently assessed by masked human graders, including optometrists and a retina specialist. Diagnostic performance was measured using sensitivity, specificity, and positive and negative predictive values. Results: A total of 272 images from 136 participants (mean age 67.7 years; 62% female) were analyzed. Human graders classified more than 97% of images as gradable, with DR detected in 47% of the images. AI-1 demonstrated the highest sensitivity (Forus: 97.5% (0.956–0.994); Intuvision: 81.7% (0.768–0.867)) but comparatively low specificity: 62.7% (58.6–66.8) and 53.8% (0.474–0.602). AI-2 displayed a balanced performance (sensitivity 80.0% and 77.0%; specificity 95.7% and 92.0%). AI-3 had a moderate sensitivity (73–80%) with the specificity ranging from 82% to 86%. Conclusion: AI performance varied across camera platforms, highlighting the need for context-specific validation to ensure safe integration into primary care and guide DR screening guidelines.

Indian Journal of Ophthalmology
Frimley Health NHS Foundation Trust (GB), London School of Hygiene & Tropical Medicine (GB), National Institute of Medical Statistics (IN), Post Graduate Institute of Medical Education and Research (IN), Anglia Ruskin University (GB)
Good health and well-being
Openalex Percentile: Top 8%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.