Effectiveness of Over‐the‐Counter Hearing Aids Versus Professionally Fitted Devices: A Systematic Review and Meta‐analysis

OBJECTIVE: To systematically review and meta-analyze the clinical effectiveness of self-fitting over-the-counter (OTC) hearing aids compared with professionally fitted devices. DATA SOURCES: PubMed, Scopus, Web of Science, Food and Drug Administration (FDA) 510(k) and De Novo databases, and ClinicalTrials.gov were searched in March 2025 and updated in August 2025. Reference lists were screened, and manufacturers were contacted for unpublished data. REVIEW METHODS: Two reviewers conducted screening, full-text review, and risk-of-bias assessment. Eligible studies were field trials comparing FDA-cleared self-fitting OTC hearing aids or software with audiologist-fitted prescription devices in adults. A random-effects meta-analysis using Hedges' g was performed. Risk of bias was evaluated with RoB 2 and ROBINS-I, and certainty of evidence with GRADE. RESULTS: From 712 records, 24 were included, representing 15 unique studies with 774 participants (739 analyzed). Most were short-term field trials (10 days to 8 weeks) comparing self-fitting and professional fittings of the same device. Pooled analyses showed no significant differences between groups for the Abbreviated Profile of Hearing Aid Benefit (Hedges' g = -0.05; 95% CI, -0.19 to 0.09), Speech, Spatial and Qualities of Hearing Scale - 12 (g = 0.01; 95% CI, -0.33 to 0.36), International Outcome Inventory for Hearing Aids (g = 0.12; 95% CI, -0.35 to 0.59), and Quick Speech-in-Noise test (g = 0.03; 95% CI, -0.22 to 0.28). Risk of bias was moderate to high, and certainty of evidence was low. CONCLUSION: Based largely on patient-reported measures, self-fitting OTC hearing aids provide outcomes comparable to professionally fitted devices. Larger, independent trials within standard clinical pathways are warranted.

Authors

Institutions

Publication Details

Journal
Otolaryngology
Published
2026-06-17
DOI
https://doi.org/10.1002/ohn.70306
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of Over‐the‐Counter Hearing Aids Versus Professionally Fitted Devices: A Systematic Review and Meta‐analysis

Ibrahim Almufarrij, De Wet Swanepoel, Megan Kruger, Karina C. De Sousa et al.
Otolaryngology
Hearing Loss and Rehabilitation
article

Effectiveness of Over‐the‐Counter Hearing Aids Versus Professionally Fitted Devices: A Systematic Review and Meta‐analysis

Ibrahim Almufarrij, De Wet Swanepoel, Megan Kruger, Karina C. De Sousa, Vinaya Manchaiah, Kevin J. Munro
article en

Abstract

OBJECTIVE: To systematically review and meta-analyze the clinical effectiveness of self-fitting over-the-counter (OTC) hearing aids compared with professionally fitted devices. DATA SOURCES: PubMed, Scopus, Web of Science, Food and Drug Administration (FDA) 510(k) and De Novo databases, and ClinicalTrials.gov were searched in March 2025 and updated in August 2025. Reference lists were screened, and manufacturers were contacted for unpublished data. REVIEW METHODS: Two reviewers conducted screening, full-text review, and risk-of-bias assessment. Eligible studies were field trials comparing FDA-cleared self-fitting OTC hearing aids or software with audiologist-fitted prescription devices in adults. A random-effects meta-analysis using Hedges' g was performed. Risk of bias was evaluated with RoB 2 and ROBINS-I, and certainty of evidence with GRADE. RESULTS: From 712 records, 24 were included, representing 15 unique studies with 774 participants (739 analyzed). Most were short-term field trials (10 days to 8 weeks) comparing self-fitting and professional fittings of the same device. Pooled analyses showed no significant differences between groups for the Abbreviated Profile of Hearing Aid Benefit (Hedges' g = -0.05; 95% CI, -0.19 to 0.09), Speech, Spatial and Qualities of Hearing Scale - 12 (g = 0.01; 95% CI, -0.33 to 0.36), International Outcome Inventory for Hearing Aids (g = 0.12; 95% CI, -0.35 to 0.59), and Quick Speech-in-Noise test (g = 0.03; 95% CI, -0.22 to 0.28). Risk of bias was moderate to high, and certainty of evidence was low. CONCLUSION: Based largely on patient-reported measures, self-fitting OTC hearing aids provide outcomes comparable to professionally fitted devices. Larger, independent trials within standard clinical pathways are warranted.

Otolaryngology
University of Colorado Hospital (US), Manipal Academy of Higher Education (IN), Manchester Academic Health Science Centre (GB), King Saud Medical City (SA), King Saud University (SA), University of Manchester (GB), Manchester University NHS Foundation Trust (GB), University of Pretoria (ZA), University of Colorado Denver (US)
Good health and well-being
Openalex Percentile: Top 6%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.