Full State Feedback Control with Observer for Multi Variable Temperature Regulation in Vapour Compression Refrigeration Systems

Achieving tight and reliable temperature regulation across all functional components of a vapour-compression refrigeration system remains a persistent challenge, primarily because classical control strategies struggle to account for the multi-dimensional, nonlinear, and coupled thermal dynamics inherent to such systems. This paper presents the design, analysis, and simulation-based validation of a full state feedback controller augmented with an observer for multi-variable temperature control of a single-stage vapour-compression refrigeration system. The plant model, derived by applying energy conservation principles to each of the four major components — evaporator, compressor, condenser, and expansion valve — is cast in state-space form, and its controllability and observability are analytically confirmed. A pole placement approach is employed to compute the state feedback gain matrix K, a forward path gain Kf is subsequently introduced to enforce zero steady-state tracking, and a Luenberger observer is designed to estimate unmeasured system states, thereby reducing reliance on physical sensors. MATLAB/Simulink simulations are conducted across five progressive design stages, and transient response metrics — rise time, settling time, peak overshoot, and steady-state error — are extracted and benchmarked. The proposed full state feedback controller with forward gain and observer achieves rise times of approximately 1.1 s for the evaporator and compressor and 0.732 s for the condenser and expansion valve, with settling times below 2.0 s, zero peak overshoot, and zero steady-state error. Practical validation with realistic operating temperatures confirms the controller's capacity to track and maintain desired temperatures for efficient cooling.

Authors

Publication Details

Journal
Iconic Research and Engineering Journals
Published
2026-06-17
DOI
https://doi.org/10.64388/irev9i10-1716088
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full State Feedback Control with Observer for Multi Variable Temperature Regulation in Vapour Compression Refrigeration Systems

A. J. Atuchukwu, Nnaemeka C. Asiegbu, Kelechi O. Onunwor, C. N. Muoghalu
Iconic Research and Engineering Journals
Refrigeration and Air Conditioning Technologies
article

Full State Feedback Control with Observer for Multi Variable Temperature Regulation in Vapour Compression Refrigeration Systems

A. J. Atuchukwu, Nnaemeka C. Asiegbu, Kelechi O. Onunwor, C. N. Muoghalu
article en

Abstract

Achieving tight and reliable temperature regulation across all functional components of a vapour-compression refrigeration system remains a persistent challenge, primarily because classical control strategies struggle to account for the multi-dimensional, nonlinear, and coupled thermal dynamics inherent to such systems. This paper presents the design, analysis, and simulation-based validation of a full state feedback controller augmented with an observer for multi-variable temperature control of a single-stage vapour-compression refrigeration system. The plant model, derived by applying energy conservation principles to each of the four major components — evaporator, compressor, condenser, and expansion valve — is cast in state-space form, and its controllability and observability are analytically confirmed. A pole placement approach is employed to compute the state feedback gain matrix K, a forward path gain Kf is subsequently introduced to enforce zero steady-state tracking, and a Luenberger observer is designed to estimate unmeasured system states, thereby reducing reliance on physical sensors. MATLAB/Simulink simulations are conducted across five progressive design stages, and transient response metrics — rise time, settling time, peak overshoot, and steady-state error — are extracted and benchmarked. The proposed full state feedback controller with forward gain and observer achieves rise times of approximately 1.1 s for the evaporator and compressor and 0.732 s for the condenser and expansion valve, with settling times below 2.0 s, zero peak overshoot, and zero steady-state error. Practical validation with realistic operating temperatures confirms the controller's capacity to track and maintain desired temperatures for efficient cooling.

Iconic Research and Engineering JournalsVol. 9(10)
Openalex Percentile: Top 12%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.