A TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study

Additively manufactured (AM)-enabled cellular architectures with tuneable mechanical properties offer new opportunities for design optimisation in orthopaedic implants. In paediatric proximal femoral osteotomy (PFO), conventional implants provide structural integrity and fixation stability, but their high stiffness reduces load transfer to the growing bone (stress shielding). Triply periodic minimal surface (TPMS) lattices exemplify AM-enabled architectures with favourable strength-to-stiffness trade-offs. This study presents a proof-of-concept of a TPMS-integrated Ti-6Al-4V paediatric PFO implant, benchmarked against conventional designs using a patient-specific digital-twin workflow coupling neuromusculoskeletal (NMSK) simulations with finite element analysis (FEA) of bone-implant mechanics. NMSK-derived joint contact and muscle forces were applied to assess von Mises stresses (implant safety), bone-implant micromotion (implant attachment), and cortical mechanical stimulus through strain energy density and microstrain metrics (stress shielding). All implants remained below the relevant material yield-strength range and exhibited micromotion within the accepted threshold. The TPMS-integrated design increased distal cortical strain energy density by 25% relative to the solid plates and reduced the cortical volume falling below the selected microstrain-based disuse threshold. The TPMS implant also generated a more uniform strain distribution near screw interfaces. These engineering metrics suggest that the TPMS design may meet key initial mechanical performance requirements while improving implant-to-bone mechanical compatibility, motivating further fatigue characterisation, experimental validation, and multi-subject studies.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2026-06-17
DOI
https://doi.org/10.1016/j.compbiomed.2026.111813
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study

Emmanuel Eghan‐Acquah, Alireza Y Bavil, Zia Javanbakht, S. Feih et al.
Computers in Biology and Medicine
Orthopaedic implants and arthroplasty
article

A TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study

Emmanuel Eghan‐Acquah, Alireza Y Bavil, Zia Javanbakht, S. Feih, David G. Lloyd, Martina Barzan, Christopher P. Carty, Ali Ebrahimzadeh Dehaghani
article en

Abstract

Additively manufactured (AM)-enabled cellular architectures with tuneable mechanical properties offer new opportunities for design optimisation in orthopaedic implants. In paediatric proximal femoral osteotomy (PFO), conventional implants provide structural integrity and fixation stability, but their high stiffness reduces load transfer to the growing bone (stress shielding). Triply periodic minimal surface (TPMS) lattices exemplify AM-enabled architectures with favourable strength-to-stiffness trade-offs. This study presents a proof-of-concept of a TPMS-integrated Ti-6Al-4V paediatric PFO implant, benchmarked against conventional designs using a patient-specific digital-twin workflow coupling neuromusculoskeletal (NMSK) simulations with finite element analysis (FEA) of bone-implant mechanics. NMSK-derived joint contact and muscle forces were applied to assess von Mises stresses (implant safety), bone-implant micromotion (implant attachment), and cortical mechanical stimulus through strain energy density and microstrain metrics (stress shielding). All implants remained below the relevant material yield-strength range and exhibited micromotion within the accepted threshold. The TPMS-integrated design increased distal cortical strain energy density by 25% relative to the solid plates and reduced the cortical volume falling below the selected microstrain-based disuse threshold. The TPMS implant also generated a more uniform strain distribution near screw interfaces. These engineering metrics suggest that the TPMS design may meet key initial mechanical performance requirements while improving implant-to-bone mechanical compatibility, motivating further fatigue characterisation, experimental validation, and multi-subject studies.

Computers in Biology and MedicineVol. 213
Griffith University (AU)
Australian Research Council
Openalex Percentile: Top 7%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.