Correcting motion-related B0 inhomogeneities in magnetic resonance imaging via combined spherical harmonics and AC/DC matrix coils using DL-based prediction–simulation study
Abstract MR data quality depends on static magnetic field (B 0 ) homogeneity. At the beginning of each session, a brief field map quantifies subject-specific B 0 variation, and shim coils are then set to counteract it. Conventional spherical-harmonic (SPH) shims have limited shimming power, motivating localized multi-coil (AC/DC) systems. However, subject motion can perturb the optimized field, necessitating real-time shim updates that require rapid tracking of B 0 changes. We simulated real-time shimming under motion using jointly first-order SPH and a 31-channel AC/DC matrix coil. Measured B 0 data initially shimmed with SPH were augmented with AC/DC terms in simulation, and real-time control was evaluated. Shimming with AC/DC coils added to the SPH coils improved field homogeneity, but motion eroded these gains. With simulated real-time updates informed by deep learning, B 0 homogeneity was effectively maintained even during substantial motion. Performance matched simulated navigator-like real-time shimming with gradient-echo and echo-planar imaging, while adding no extra scan time in main imaging sequences. Multi-coil shimming offers clear benefits, but the gains may be reduced if shim terms are not updated in real time. Deep-learning-driven prediction of B 0 changes provides a practical path to sequence-agnostic, motion-robust shimming across a broad range of MR protocols.
Authors
- Wolfgang Bogner (ORCID: https://orcid.org/0000-0002-0130-3463)
- Stanislav Motyka (ORCID: https://orcid.org/0000-0002-6314-316X)
- Beata Bachrátá (ORCID: https://orcid.org/0000-0002-3352-8966)
- Christian Menard (ORCID: https://orcid.org/0000-0002-7134-8384)
- Bernhard Strasser (ORCID: https://orcid.org/0000-0001-9542-3855)
- Georg Langs
- Jason Stockmann
- Mohammad Khosravi
- Günther Grabner
Institutions
- Harvard University (US)
- Austrian Research Institute for Artificial Intelligence (AT)
- Massachusetts General Hospital (US)
- Comprehensive Cancer Center Vienna (AT)
- Christian Doppler Laboratory for Thermoelectricity (AT)
- Athinoula A. Martinos Center for Biomedical Imaging (US)
- FH Kärnten (AT)
- Medical University of Vienna (AT)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-06-16
- DOI
- https://doi.org/10.1038/s41598-026-56900-z
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Austrian Science Fund
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering