Correcting motion-related B0 inhomogeneities in magnetic resonance imaging via combined spherical harmonics and AC/DC matrix coils using DL-based prediction–simulation study

Abstract MR data quality depends on static magnetic field (B 0 ) homogeneity. At the beginning of each session, a brief field map quantifies subject-specific B 0 variation, and shim coils are then set to counteract it. Conventional spherical-harmonic (SPH) shims have limited shimming power, motivating localized multi-coil (AC/DC) systems. However, subject motion can perturb the optimized field, necessitating real-time shim updates that require rapid tracking of B 0 changes. We simulated real-time shimming under motion using jointly first-order SPH and a 31-channel AC/DC matrix coil. Measured B 0 data initially shimmed with SPH were augmented with AC/DC terms in simulation, and real-time control was evaluated. Shimming with AC/DC coils added to the SPH coils improved field homogeneity, but motion eroded these gains. With simulated real-time updates informed by deep learning, B 0 homogeneity was effectively maintained even during substantial motion. Performance matched simulated navigator-like real-time shimming with gradient-echo and echo-planar imaging, while adding no extra scan time in main imaging sequences. Multi-coil shimming offers clear benefits, but the gains may be reduced if shim terms are not updated in real time. Deep-learning-driven prediction of B 0 changes provides a practical path to sequence-agnostic, motion-robust shimming across a broad range of MR protocols.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-16
DOI
https://doi.org/10.1038/s41598-026-56900-z
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correcting motion-related B0 inhomogeneities in magnetic resonance imaging via combined spherical harmonics and AC/DC matrix coils using DL-based prediction–simulation study

Wolfgang Bogner, Stanislav Motyka, Beata Bachrátá, Christian Menard et al.
Scientific Reports
Advanced MRI Techniques and Applications
article

Correcting motion-related B0 inhomogeneities in magnetic resonance imaging via combined spherical harmonics and AC/DC matrix coils using DL-based prediction–simulation study

Wolfgang Bogner, Stanislav Motyka, Beata Bachrátá, Christian Menard, Bernhard Strasser, Georg Langs, Jason Stockmann, Mohammad Khosravi, Günther Grabner
article en

Abstract

Abstract MR data quality depends on static magnetic field (B 0 ) homogeneity. At the beginning of each session, a brief field map quantifies subject-specific B 0 variation, and shim coils are then set to counteract it. Conventional spherical-harmonic (SPH) shims have limited shimming power, motivating localized multi-coil (AC/DC) systems. However, subject motion can perturb the optimized field, necessitating real-time shim updates that require rapid tracking of B 0 changes. We simulated real-time shimming under motion using jointly first-order SPH and a 31-channel AC/DC matrix coil. Measured B 0 data initially shimmed with SPH were augmented with AC/DC terms in simulation, and real-time control was evaluated. Shimming with AC/DC coils added to the SPH coils improved field homogeneity, but motion eroded these gains. With simulated real-time updates informed by deep learning, B 0 homogeneity was effectively maintained even during substantial motion. Performance matched simulated navigator-like real-time shimming with gradient-echo and echo-planar imaging, while adding no extra scan time in main imaging sequences. Multi-coil shimming offers clear benefits, but the gains may be reduced if shim terms are not updated in real time. Deep-learning-driven prediction of B 0 changes provides a practical path to sequence-agnostic, motion-robust shimming across a broad range of MR protocols.

Scientific Reports
Harvard University (US), Austrian Research Institute for Artificial Intelligence (AT), Massachusetts General Hospital (US), Comprehensive Cancer Center Vienna (AT), Christian Doppler Laboratory for Thermoelectricity (AT), Athinoula A. Martinos Center for Biomedical Imaging (US), FH Kärnten (AT), Medical University of Vienna (AT)
Austrian Science Fund, National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 7%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.