Bone remodelling around internal fracture fixations used for treating femoral neck fractures: A finite element analysis

Femoral neck fractures necessitate effective fracture fixation techniques to ensure optimal outcomes. The study evaluates the bone remodelling around Dynamic Hip Screw with anti-rotational screw (DHS + AR) and Femoral Neck System (FNS) used for treating femoral neck fractures of Pauwels types I, II and III. Femur models were developed using CT imaging data. Fractures were modelled assuming smooth fracture surfaces. Isotropic heterogeneous CT-grey value-based bone material properties were employed in the bone model, and Ti-alloy was incorporated as implant material. Bone remodelling algorithm based on strain energy density was employed to predict the implants’ effects under two loading conditions: normal walking and stair climbing. The density change (Δρ) was iteratively updated until convergence occurred (Δρ < 0.005 g/cm 3 between two consecutive iterations). The investigation compared post-operative (PO) conditions with equilibrium (AE) states. Results revealed that strain shielding was approximately 27% lower in FNS-implanted models than DHS + AR models, indicating better biomechanical performance under adopted modelling assumptions. From PO to AE, axial deformation and rotational stability of the femoral head were reduced more in FNS models, with reductions of up to 13.57% and 83%, respectively. Micromotion was (below 100 μm) in all models except for FNS in Pauwels III fractures under PO conditions. However, it was reduced below 100 μm at AE. Lower bone loss was observed in FNS-implanted models while DHS + AR implanted models exhibited higher resorption. These findings suggest that FNS implants are predicted to provide better stability and favourable bone remodelling outcomes compared to DHS + AR screws.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2026-06-16
DOI
https://doi.org/10.1177/09544119261461170
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bone remodelling around internal fracture fixations used for treating femoral neck fractures: A finite element analysis

Bidyut Pal, Kishore Pradeep, Swapnil Mahadev Dhobale, Biswajit Mahapatra
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Hip and Femur Fractures
article

Bone remodelling around internal fracture fixations used for treating femoral neck fractures: A finite element analysis

Bidyut Pal, Kishore Pradeep, Swapnil Mahadev Dhobale, Biswajit Mahapatra
article en

Abstract

Femoral neck fractures necessitate effective fracture fixation techniques to ensure optimal outcomes. The study evaluates the bone remodelling around Dynamic Hip Screw with anti-rotational screw (DHS + AR) and Femoral Neck System (FNS) used for treating femoral neck fractures of Pauwels types I, II and III. Femur models were developed using CT imaging data. Fractures were modelled assuming smooth fracture surfaces. Isotropic heterogeneous CT-grey value-based bone material properties were employed in the bone model, and Ti-alloy was incorporated as implant material. Bone remodelling algorithm based on strain energy density was employed to predict the implants’ effects under two loading conditions: normal walking and stair climbing. The density change (Δρ) was iteratively updated until convergence occurred (Δρ < 0.005 g/cm 3 between two consecutive iterations). The investigation compared post-operative (PO) conditions with equilibrium (AE) states. Results revealed that strain shielding was approximately 27% lower in FNS-implanted models than DHS + AR models, indicating better biomechanical performance under adopted modelling assumptions. From PO to AE, axial deformation and rotational stability of the femoral head were reduced more in FNS models, with reductions of up to 13.57% and 83%, respectively. Micromotion was (below 100 μm) in all models except for FNS in Pauwels III fractures under PO conditions. However, it was reduced below 100 μm at AE. Lower bone loss was observed in FNS-implanted models while DHS + AR implanted models exhibited higher resorption. These findings suggest that FNS implants are predicted to provide better stability and favourable bone remodelling outcomes compared to DHS + AR screws.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Indian Institute of Engineering Science and Technology, Shibpur (IN)
Affordable and clean energy
Openalex Percentile: Top 6%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.