Applying MLP and SVM Models to Detect Potential Damages on High-Voltage Power Transmission Towers and Lines Using Multi-Temporal SAR Images

The essential role of electricity supply for public and private services highlights the need to monitor the stability of power transmission networks during, or immediately after, hazardous events. In the aftermath of calamities, traditional field inspections may be impractical or unsafe, leaving operators without timely information on the condition of critical assets. In this paper, we present and discuss the performance of two automatic Artificial Intelligence (AI)-based models (Multi-Layer Perceptron (MLP) neural network architectures and Support Vector Machine (SVM) model) designed to automatically assess the status of high-voltage transmission towers and power lines through multi-temporal spaceborne Synthetic Aperture Radar (SAR) image analysis. Model development and testing rely on real COSMO-SkyMed Stripmap observations of damaged towers and power lines affected by documented hazardous events across Italy, complemented by simulated tower data generated with a physics-guided, signature-based SAR simulator designed to preserve the observed target-to-background contrast and spatial footprint patterns of real SAR tower signatures. Results indicate that the MLP, trained on either real or simulated data, achieved 100% Overall Accuracy (OA) with no observed false positives or false negatives within the considered visibility-screened real test set, while providing inference times on the order of tenths of milliseconds per target… Computational performance characteristics, operational advantages, and the potential pathway toward satellite on-board porting are discussed to enhance situational awareness and support the prioritisation of interventions during critical events.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2026-06-16
DOI
https://doi.org/10.3390/rs18121998
Primary Topic
Synthetic Aperture Radar (SAR) Applications and Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applying MLP and SVM Models to Detect Potential Damages on High-Voltage Power Transmission Towers and Lines Using Multi-Temporal SAR Images

Cataldo Guaragnella, Khalid Tijani, Alessandro Parisi, Alberto Morea et al.
Remote Sensing
Synthetic Aperture Radar (SAR) Applications and Techniques
article

Applying MLP and SVM Models to Detect Potential Damages on High-Voltage Power Transmission Towers and Lines Using Multi-Temporal SAR Images

Cataldo Guaragnella, Khalid Tijani, Alessandro Parisi, Alberto Morea, Davide Oscar Nitti, A. Bigazzi, Gabriele Mascetti, Raffaele Nutricato, Maria Virelli, Gianluca Pari, Enrico Sain, Filomena Ciola, Mirko Di Noia
article en

Abstract

The essential role of electricity supply for public and private services highlights the need to monitor the stability of power transmission networks during, or immediately after, hazardous events. In the aftermath of calamities, traditional field inspections may be impractical or unsafe, leaving operators without timely information on the condition of critical assets. In this paper, we present and discuss the performance of two automatic Artificial Intelligence (AI)-based models (Multi-Layer Perceptron (MLP) neural network architectures and Support Vector Machine (SVM) model) designed to automatically assess the status of high-voltage transmission towers and power lines through multi-temporal spaceborne Synthetic Aperture Radar (SAR) image analysis. Model development and testing rely on real COSMO-SkyMed Stripmap observations of damaged towers and power lines affected by documented hazardous events across Italy, complemented by simulated tower data generated with a physics-guided, signature-based SAR simulator designed to preserve the observed target-to-background contrast and spatial footprint patterns of real SAR tower signatures. Results indicate that the MLP, trained on either real or simulated data, achieved 100% Overall Accuracy (OA) with no observed false positives or false negatives within the considered visibility-screened real test set, while providing inference times on the order of tenths of milliseconds per target… Computational performance characteristics, operational advantages, and the potential pathway toward satellite on-board porting are discussed to enhance situational awareness and support the prioritisation of interventions during critical events.

Remote SensingVol. 18(12)
Agenzia Spaziale Italiana (IT), Planetek Italia (IT), Geophysical Laboratory (US), Polytechnic University of Bari (IT)
Agenzia Spaziale Italiana
Openalex Percentile: Top 3%
Synthetic Aperture Radar (SAR) Applications and Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.