Performance Evaluation of a Commercial LC-HRMS Platform for Untargeted Whole Blood Analysis: Comparison with Immunoassay and LRMS Urine Screening and Targeted LC-MS/MS (MRM) Whole Blood Quantification

In forensic toxicology (FT), drug of abuse (DoA) screening is essential yet challenging. This study presents a vendor-based, high-resolution (HR) LC-MS/MS blood screening method implemented without in‑house optimization, in comparison to immunoassay-based and low-resolution (LR) urine screening approaches simultaneous to (semi)quantification. The HR-method allows detection of more than 3000 analytes, including DoAs, drugs, and suspected new psychoactive substances (NPS). Following protein precipitation, analytes qualitatively identified in 500 authentic whole-blood samples using the HR-method were qualitatively compared with results from immunoassay and LR urine screening. Additionally, 82 common DoAs and drugs were (semi)quantitatively validated according to ANSI and GTFCh guidelines, and quantitative performance was assessed against a fully-validated targeted LC-MS/MS method (MRM mode). In total, the HR-method detected 819 (83%) of the 994 analytes identified by LR urine screening. Substances not captured by the HR approach typically showed concentrations below the identification limit and/or were of negligible relevance in FT. The HR blood screening detected 66% of all cases positive for THC and/or its metabolites, whereas the LR urine screening failed to detect these compounds entirely. Incorporation of the HighResNPS® database enabled the tentative identification of 14 NPS. Seventy-four (90%) of the 82 DoAs demonstrated accuracy within ±30%, precision (CV) ≤30%, and quantitative results of 100 authentic cases were consistent with those from the targeted LC-MS/MS method which is generally considered the gold standard for quantification. Overall, the HR blood screening can replace LR urine screening enabling simultaneous detection of DoAs, their metabolites, and NPS. The (semi)quantitative validation of 74 drugs and the quantitative comparison confirmed the method's reliability in distinguishing between subtherapeutic, therapeutic, and toxic concentrations without the need for drug class-specific optimization, thereby saving time, effort, and costs. This untargeted approach combines screening with (semi)quantification while supporting routine workflows, research applications, and retrospective analysis of new emerging substances.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Toxicology
Published
2026-06-16
DOI
https://doi.org/10.1093/jat/bkag050
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of a Commercial LC-HRMS Platform for Untargeted Whole Blood Analysis: Comparison with Immunoassay and LRMS Urine Screening and Targeted LC-MS/MS (MRM) Whole Blood Quantification

Lana Brockbals, Thomas Kræmer, Andrea Eva Steuer, Annina Bovens
Journal of Analytical Toxicology
Forensic Toxicology and Drug Analysis
article

Performance Evaluation of a Commercial LC-HRMS Platform for Untargeted Whole Blood Analysis: Comparison with Immunoassay and LRMS Urine Screening and Targeted LC-MS/MS (MRM) Whole Blood Quantification

Lana Brockbals, Thomas Kræmer, Andrea Eva Steuer, Annina Bovens
article en

Abstract

In forensic toxicology (FT), drug of abuse (DoA) screening is essential yet challenging. This study presents a vendor-based, high-resolution (HR) LC-MS/MS blood screening method implemented without in‑house optimization, in comparison to immunoassay-based and low-resolution (LR) urine screening approaches simultaneous to (semi)quantification. The HR-method allows detection of more than 3000 analytes, including DoAs, drugs, and suspected new psychoactive substances (NPS). Following protein precipitation, analytes qualitatively identified in 500 authentic whole-blood samples using the HR-method were qualitatively compared with results from immunoassay and LR urine screening. Additionally, 82 common DoAs and drugs were (semi)quantitatively validated according to ANSI and GTFCh guidelines, and quantitative performance was assessed against a fully-validated targeted LC-MS/MS method (MRM mode). In total, the HR-method detected 819 (83%) of the 994 analytes identified by LR urine screening. Substances not captured by the HR approach typically showed concentrations below the identification limit and/or were of negligible relevance in FT. The HR blood screening detected 66% of all cases positive for THC and/or its metabolites, whereas the LR urine screening failed to detect these compounds entirely. Incorporation of the HighResNPS® database enabled the tentative identification of 14 NPS. Seventy-four (90%) of the 82 DoAs demonstrated accuracy within ±30%, precision (CV) ≤30%, and quantitative results of 100 authentic cases were consistent with those from the targeted LC-MS/MS method which is generally considered the gold standard for quantification. Overall, the HR blood screening can replace LR urine screening enabling simultaneous detection of DoAs, their metabolites, and NPS. The (semi)quantitative validation of 74 drugs and the quantitative comparison confirmed the method's reliability in distinguishing between subtherapeutic, therapeutic, and toxic concentrations without the need for drug class-specific optimization, thereby saving time, effort, and costs. This untargeted approach combines screening with (semi)quantification while supporting routine workflows, research applications, and retrospective analysis of new emerging substances.

Journal of Analytical Toxicology
University of Zurich (CH)
Good health and well-being
Openalex Percentile: Top 8%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.