Cone-beam computed tomography evaluation of palatal bone and soft tissue dimensions for orthodontic miniscrew placement

Objectives: Palatal mini-implants have become essential tools in orthodontic anchorage; however, their success depends on adequate palatal hard tissue thickness and acceptable soft tissue morphology. The objective of this study is to evaluate the thickness and distribution of suitable sites for palatal orthodontic mini-implant placement using cone-beam computed tomography (CBCT). Material and Methods: This retrospective analysis of CBCT images from forty-nine subjects (24 males, 25 females; age range 14–30 years) was conducted. Subjects were categorized into adolescents ( n = 24) and adults ( n = 25). Palatal hard tissue, soft tissue, and combined thickness were measured at four coronal planes corresponding to the first premolar (PM1), second premolar (PM2), first molar (M1), and second molar (M2) regions. Measurements were obtained bilaterally at 1-mm intervals from the midpalatal suture up to 10 mm laterally. Intra-examiner reliability was assessed using the intraclass correlation coefficient (ICC). A post hoc power analysis was performed to evaluate the adequacy of the sample size for detecting sex-related differences. Statistical analysis included two-way analysis of variance (ANOVA) to evaluate the effects of coronal plane and distance from the midline, along with one-way ANOVA and Mann–Whitney U tests to assess age and sex-related differences. Statistical significance was set at p < 0.05. Results: Intra-examiner reliability demonstrated good reproducibility (ICC = 0.766; 95% confidence interval: 0.537–0.890; p < 0.001). Palatal hard tissue thickness showed a consistent V-shaped distribution across all coronal planes, with maximum thickness at the midpalatal suture, minimum at 2–3 mm lateral to the midline, and gradual increase toward 10 mm. Mean hard tissue thickness differed significantly among planes ( p < 0.001), being greatest in the PM1 region (5.2 ± 1.4 mm), followed by the PM2 (4.8 ± 1.3 mm), M1 (4.1 ± 1.2 mm), and M2 regions (3.7 ± 1.1 mm). Combined hard and soft tissue thickness ≥7 mm was consistently observed in the PM1 and PM2 regions at 1–5 mm from the midpalatal suture in both adolescents and adults. Two-way ANOVA showed significant effects of coronal plane and distance from the midline ( p < 0.05). No statistically significant effects of age and sex were observed ( p > 0.05); however, post hoc power analysis revealed low statistical power (7.4%) to detect small differences between sexes, with observed effect sizes ranging from r = 0.022 to 0.305, indicating that the study was underpowered for detecting subtle sex-related variations. Conclusion: Palatal hard tissue thickness follows a consistent V-pattern with the PM1 and PM2 regions, particularly at positions 1–5 mm lateral to the midpalatal suture, which provide the most favorable anatomical conditions for safe and predictable palatal miniscrew placement.

Authors

Institutions

Publication Details

Journal
APOS Trends in Orthodontics
Published
2026-06-16
DOI
https://doi.org/10.25259/apos_14_2026
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cone-beam computed tomography evaluation of palatal bone and soft tissue dimensions for orthodontic miniscrew placement

Anand Marya, V R Reddy, Rakesh Rao Annamaneni, Akshay Goje et al.
APOS Trends in Orthodontics
Orthodontics and Dentofacial Orthopedics
article

Cone-beam computed tomography evaluation of palatal bone and soft tissue dimensions for orthodontic miniscrew placement

Anand Marya, V R Reddy, Rakesh Rao Annamaneni, Akshay Goje, Prasad Nalabothu, V. Deepti, Abhiram Kante
article en

Abstract

Objectives: Palatal mini-implants have become essential tools in orthodontic anchorage; however, their success depends on adequate palatal hard tissue thickness and acceptable soft tissue morphology. The objective of this study is to evaluate the thickness and distribution of suitable sites for palatal orthodontic mini-implant placement using cone-beam computed tomography (CBCT). Material and Methods: This retrospective analysis of CBCT images from forty-nine subjects (24 males, 25 females; age range 14–30 years) was conducted. Subjects were categorized into adolescents ( n = 24) and adults ( n = 25). Palatal hard tissue, soft tissue, and combined thickness were measured at four coronal planes corresponding to the first premolar (PM1), second premolar (PM2), first molar (M1), and second molar (M2) regions. Measurements were obtained bilaterally at 1-mm intervals from the midpalatal suture up to 10 mm laterally. Intra-examiner reliability was assessed using the intraclass correlation coefficient (ICC). A post hoc power analysis was performed to evaluate the adequacy of the sample size for detecting sex-related differences. Statistical analysis included two-way analysis of variance (ANOVA) to evaluate the effects of coronal plane and distance from the midline, along with one-way ANOVA and Mann–Whitney U tests to assess age and sex-related differences. Statistical significance was set at p < 0.05. Results: Intra-examiner reliability demonstrated good reproducibility (ICC = 0.766; 95% confidence interval: 0.537–0.890; p < 0.001). Palatal hard tissue thickness showed a consistent V-shaped distribution across all coronal planes, with maximum thickness at the midpalatal suture, minimum at 2–3 mm lateral to the midline, and gradual increase toward 10 mm. Mean hard tissue thickness differed significantly among planes ( p < 0.001), being greatest in the PM1 region (5.2 ± 1.4 mm), followed by the PM2 (4.8 ± 1.3 mm), M1 (4.1 ± 1.2 mm), and M2 regions (3.7 ± 1.1 mm). Combined hard and soft tissue thickness ≥7 mm was consistently observed in the PM1 and PM2 regions at 1–5 mm from the midpalatal suture in both adolescents and adults. Two-way ANOVA showed significant effects of coronal plane and distance from the midline ( p < 0.05). No statistically significant effects of age and sex were observed ( p > 0.05); however, post hoc power analysis revealed low statistical power (7.4%) to detect small differences between sexes, with observed effect sizes ranging from r = 0.022 to 0.305, indicating that the study was underpowered for detecting subtle sex-related variations. Conclusion: Palatal hard tissue thickness follows a consistent V-pattern with the PM1 and PM2 regions, particularly at positions 1–5 mm lateral to the midpalatal suture, which provide the most favorable anatomical conditions for safe and predictable palatal miniscrew placement.

APOS Trends in OrthodonticsVol. 0
University Hospital of Basel (CH), University of Puthisastra (KH), Sri Rajiv Gandhi College of Dental Sciences and Hospital (IN)
Openalex Percentile: Top 6%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.