Diagnostic Value of Quantitative Lung Perfusion Single-photon Emission CT/CT for Chronic Lung Allograft Dysfunction in Patients After Bilateral Lung Transplantation

BACKGROUND: Chronic lung allograft dysfunction (CLAD) is a major cause of late morbidity after lung transplantation, and spirometry lacks the ability to detect regional lung changes. Thus, in this study, we investigated whether quantitative perfusion single-photon emission CT/CT parameters can distinguish CLAD from non-CLAD lungs and how they relate to pulmonary function. PATIENTS AND METHODS: This retrospective study included 80 lung transplant recipients who underwent SPECT/CT. Standardized uptake value (SUV)mean, total lung uptake (TLU), and percentage injected dose (%ID) were calculated, and group differences, receiver operating characteristic performance, and correlations with forced expiratory volume in 1 second, forced vital capacity, and total lung capacity were analyzed. RESULTS: No significant difference was observed for SUVmean (P = 0.250), whereas TLU and %ID were significantly lower in CLAD (P < 0.0001). Area under the curve values were 0.56 (SUVmean), 0.76 (TLU), and 0.78 (%ID). %ID showed the best accuracy (cutoff: 0.83; sensitivity: 65.0%; specificity: 83.8%). CONCLUSIONS: Volume-based metrics, especially %ID, serve as useful noninvasive indicators for the assessment of CLAD.

Authors

Institutions

Publication Details

Journal
Clinical Nuclear Medicine
Published
2026-06-16
DOI
https://doi.org/10.1097/rlu.0000000000006557
Primary Topic
Transplantation: Methods and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Value of Quantitative Lung Perfusion Single-photon Emission CT/CT for Chronic Lung Allograft Dysfunction in Patients After Bilateral Lung Transplantation

Hiraki Takao, Shinichi Toyooka, Fumiyo Higaki, Toshihiro Iguchi et al.
Clinical Nuclear Medicine
Transplantation: Methods and Outcomes
article

Diagnostic Value of Quantitative Lung Perfusion Single-photon Emission CT/CT for Chronic Lung Allograft Dysfunction in Patients After Bilateral Lung Transplantation

Hiraki Takao, Shinichi Toyooka, Fumiyo Higaki, Toshihiro Iguchi, Seiichiro Sugimoto, Masahiro Nakashima
article en

Abstract

BACKGROUND: Chronic lung allograft dysfunction (CLAD) is a major cause of late morbidity after lung transplantation, and spirometry lacks the ability to detect regional lung changes. Thus, in this study, we investigated whether quantitative perfusion single-photon emission CT/CT parameters can distinguish CLAD from non-CLAD lungs and how they relate to pulmonary function. PATIENTS AND METHODS: This retrospective study included 80 lung transplant recipients who underwent SPECT/CT. Standardized uptake value (SUV)mean, total lung uptake (TLU), and percentage injected dose (%ID) were calculated, and group differences, receiver operating characteristic performance, and correlations with forced expiratory volume in 1 second, forced vital capacity, and total lung capacity were analyzed. RESULTS: No significant difference was observed for SUVmean (P = 0.250), whereas TLU and %ID were significantly lower in CLAD (P < 0.0001). Area under the curve values were 0.56 (SUVmean), 0.76 (TLU), and 0.78 (%ID). %ID showed the best accuracy (cutoff: 0.83; sensitivity: 65.0%; specificity: 83.8%). CONCLUSIONS: Volume-based metrics, especially %ID, serve as useful noninvasive indicators for the assessment of CLAD.

Clinical Nuclear Medicine
Okayama University (JP), Saudi Center for Organ Transplantation (SA), Foundation for International Environmental Law and Development (GB), Okayama University Hospital (JP), Department of Health (ZA)
Good health and well-being
Openalex Percentile: Top 6%
Transplantation: Methods and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.