Assessment of Electrical Resistance Sensors Sensitivity to Localized Corrosion

ABSTRACT This paper investigates the sensitivity of electrical resistance (ER) sensors to localized corrosion. Analytical models were developed to simulate the ER sensor response to various geometries of localized attacks. These theoretical predictions were validated against experimental data, including controlled electrochemical dissolution and realistic sodium chloride exposure. The comparison revealed a strong correlation between the models and experimental measurements, highlighting a critical limitation of the resistometric method: ER sensors severely underestimate the actual depth of localized attacks. Specifically, models demonstrate that for a localized attack covering less than 5% of the sensor's measuring area, a defect consuming 80% of the initial thickness yields an apparent overall sensor reading of merely 20% thickness loss. Furthermore, under practical NaCl exposure scenarios, actual pit depths reaching 50 µm resulted in sensor readings of only 11 µm. These findings are essential for the accurate interpretation of ER sensor data and the implementation of appropriate safety margins in industrial applications.

Authors

Institutions

Publication Details

Journal
Materials and Corrosion
Published
2026-06-16
DOI
https://doi.org/10.1002/maco.70188
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Electrical Resistance Sensors Sensitivity to Localized Corrosion

Milan Kouřil, Matěj Reiser
Materials and Corrosion
Hydrogen embrittlement and corrosion behaviors in metals
article

Assessment of Electrical Resistance Sensors Sensitivity to Localized Corrosion

Milan Kouřil, Matěj Reiser
article en

Abstract

ABSTRACT This paper investigates the sensitivity of electrical resistance (ER) sensors to localized corrosion. Analytical models were developed to simulate the ER sensor response to various geometries of localized attacks. These theoretical predictions were validated against experimental data, including controlled electrochemical dissolution and realistic sodium chloride exposure. The comparison revealed a strong correlation between the models and experimental measurements, highlighting a critical limitation of the resistometric method: ER sensors severely underestimate the actual depth of localized attacks. Specifically, models demonstrate that for a localized attack covering less than 5% of the sensor's measuring area, a defect consuming 80% of the initial thickness yields an apparent overall sensor reading of merely 20% thickness loss. Furthermore, under practical NaCl exposure scenarios, actual pit depths reaching 50 µm resulted in sensor readings of only 11 µm. These findings are essential for the accurate interpretation of ER sensor data and the implementation of appropriate safety margins in industrial applications.

Materials and Corrosion
University of Chemistry and Technology, Prague (CZ)
Technology Agency of the Czech Republic
Quality Education
Openalex Percentile: Top 16%
Hydrogen embrittlement and corrosion behaviors in metals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of Electrical Resistance Sensors Sensitivity to Localized Corrosion — Milan Kouřil, Matěj Reiser · Materials and Corrosion (2026) | TGRS Research Map | TGRS