Artificial Intelligence for the Detection of Hypertrophic Cardiomyopathy From Standard Electrocardiogram

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is often diagnosed late, increasing avoidable risk and delaying treatment. Artificial intelligence (AI) for 12-lead electrocardiograms (ECGs) may identify undetected HCM earlier. OBJECTIVES: This study aimed to evaluate the performance of an AI algorithm for HCM detection and identify predictors of correct classification. METHODS: Of 314 patients with cardiac magnetic resonance imaging (cMRI) for suspected HCM, 150 had analyzable ECGs and confirmed HCM by physician review of medical records and cMRI (ground truth). Eighty-three control patients without cardiomyopathy were included. A proprietary algorithm, Viz HCM (Viz.ai, Inc), labeled ECGs as HCM-positive or HCM-negative; the ECG closest to each patient's cMRI date was compared to ground truth. Diagnostic performance was evaluated by the area under the curve of the receiver-operating characteristic curve and at the prespecified threshold. Predictors of correct detection were determined by multivariable logistic regression for age, sex, race, maximal wall thickness, and hypertrophy subtype. RESULTS: The mean age of all 233 patients was 56 years, and 62% were male. The algorithm identified HCM with an area under the curve of 0.946 (95% CI: 0.916-0.970), sensitivity of 58% (95% CI: 50.0%-65.6%), and specificity of 100% (95% CI: 95.6%-100%). Apical subtype was a significant predictor of correct detection (adjusted OR: 4.71; 95% CI: 1.71-15.48; P = 0.005). In 9 of 28 patients with ECGs available at least 1 year prior to cMRI, the algorithm detected HCM 2.6 years (median) before clinical diagnosis. CONCLUSIONS: The AI ECG algorithm demonstrated highly specific HCM detection confirmed by cMRI and may improve early identification of unrecognized HCM.

Authors

Institutions

Publication Details

Journal
JACC Advances
Published
2026-06-16
DOI
https://doi.org/10.1016/j.jacadv.2026.102914
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence for the Detection of Hypertrophic Cardiomyopathy From Standard Electrocardiogram

Christopher J. Love, Florian Rader, Jonathan Kermanshahchi, Sarit Meshesha et al.
JACC Advances
ECG Monitoring and Analysis
article

Artificial Intelligence for the Detection of Hypertrophic Cardiomyopathy From Standard Electrocardiogram

Christopher J. Love, Florian Rader, Jonathan Kermanshahchi, Sarit Meshesha, Alexander Kukuev, Katia Kon, Klevin Roger Reyes, Jakob Park
article en

Abstract

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is often diagnosed late, increasing avoidable risk and delaying treatment. Artificial intelligence (AI) for 12-lead electrocardiograms (ECGs) may identify undetected HCM earlier. OBJECTIVES: This study aimed to evaluate the performance of an AI algorithm for HCM detection and identify predictors of correct classification. METHODS: Of 314 patients with cardiac magnetic resonance imaging (cMRI) for suspected HCM, 150 had analyzable ECGs and confirmed HCM by physician review of medical records and cMRI (ground truth). Eighty-three control patients without cardiomyopathy were included. A proprietary algorithm, Viz HCM (Viz.ai, Inc), labeled ECGs as HCM-positive or HCM-negative; the ECG closest to each patient's cMRI date was compared to ground truth. Diagnostic performance was evaluated by the area under the curve of the receiver-operating characteristic curve and at the prespecified threshold. Predictors of correct detection were determined by multivariable logistic regression for age, sex, race, maximal wall thickness, and hypertrophy subtype. RESULTS: The mean age of all 233 patients was 56 years, and 62% were male. The algorithm identified HCM with an area under the curve of 0.946 (95% CI: 0.916-0.970), sensitivity of 58% (95% CI: 50.0%-65.6%), and specificity of 100% (95% CI: 95.6%-100%). Apical subtype was a significant predictor of correct detection (adjusted OR: 4.71; 95% CI: 1.71-15.48; P = 0.005). In 9 of 28 patients with ECGs available at least 1 year prior to cMRI, the algorithm detected HCM 2.6 years (median) before clinical diagnosis. CONCLUSIONS: The AI ECG algorithm demonstrated highly specific HCM detection confirmed by cMRI and may improve early identification of unrecognized HCM.

JACC AdvancesVol. 5(7)
Twitter (United States) (US), Cedars-Sinai Medical Center (US), Cedars-Sinai Smidt Heart Institute (US), Vibrant Data (United States) (US)
Openalex Percentile: Top 7%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.