Dosimetric Impact of Hysteresis in Gantry Rotation on Clinical VMAT Plans

Gantry angle inaccuracies during treatment delivery affect the dose distribution received by the patient. These inaccuracies may arise from stretching of the gantry belt, leading to hysteresis in the gantry angle. The purpose of this work is to determine the impact of gantry hysteresis on the dose distribution of representative VMAT plans and to evaluate whether current QA guidelines for gantry angle tolerances are adequate in these cases. Simulations were performed in Eclipse by encoding gantry errors with various amounts of hysteresis. The impact on the dose constraints and the gamma index passing rates computed relative to the as-planned dose distribution was examined in five clinical plans: brain SRS, prostate with nodes, lung SBRT and spine SBRT. The hysteresis thresholds, defined as the amount of gantry angle error causing a 1.0% dose-constraint change or a gamma reduction to 90%, were identified for GTVs, PTVs and selected OARs. D99%, D98% and gamma(1.0%,0.01mm) in the targets decreased with increasing hysteresis. The hysteresis threshold for the D98% or D99% ratios to the planned values ranged from 1.0 degree to 11.0 degrees, with the smallest value (indicating the highest sensitivity) observed in the multi-met brain plan. Thresholds for the gamma analysis ranged from 0.5 degree to 7.7 degrees, with the smallest value in the double-met lung SBRT plan. All dose metrics in the OARs decreased with increasing hysteresis, except for the D25% ratio in the bladder of the prostate/pelvis plan. The corresponding gamma passing rates decreased as hysteresis increased. Maintaining gantry hysteresis within 1.0 degree allowed DVH-based metrics to remain within 1.0% of the planned values for all targets and OARs. The corresponding gamma passing rates remained above 90% for all OARs and for all but two PTVs. Limiting hysteresis to 0.5 degree ensured that all metrics stayed within tolerance.

Authors

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-06-16
DOI
https://doi.org/10.1088/2057-1976/ae7df6
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Impact of Hysteresis in Gantry Rotation on Clinical VMAT Plans

Stanislaw Szpala
Biomedical Physics & Engineering Express
Advanced Radiotherapy Techniques
article

Dosimetric Impact of Hysteresis in Gantry Rotation on Clinical VMAT Plans

Stanislaw Szpala
article en

Abstract

Gantry angle inaccuracies during treatment delivery affect the dose distribution received by the patient. These inaccuracies may arise from stretching of the gantry belt, leading to hysteresis in the gantry angle. The purpose of this work is to determine the impact of gantry hysteresis on the dose distribution of representative VMAT plans and to evaluate whether current QA guidelines for gantry angle tolerances are adequate in these cases. Simulations were performed in Eclipse by encoding gantry errors with various amounts of hysteresis. The impact on the dose constraints and the gamma index passing rates computed relative to the as-planned dose distribution was examined in five clinical plans: brain SRS, prostate with nodes, lung SBRT and spine SBRT. The hysteresis thresholds, defined as the amount of gantry angle error causing a 1.0% dose-constraint change or a gamma reduction to 90%, were identified for GTVs, PTVs and selected OARs. D99%, D98% and gamma(1.0%,0.01mm) in the targets decreased with increasing hysteresis. The hysteresis threshold for the D98% or D99% ratios to the planned values ranged from 1.0 degree to 11.0 degrees, with the smallest value (indicating the highest sensitivity) observed in the multi-met brain plan. Thresholds for the gamma analysis ranged from 0.5 degree to 7.7 degrees, with the smallest value in the double-met lung SBRT plan. All dose metrics in the OARs decreased with increasing hysteresis, except for the D25% ratio in the bladder of the prostate/pelvis plan. The corresponding gamma passing rates decreased as hysteresis increased. Maintaining gantry hysteresis within 1.0 degree allowed DVH-based metrics to remain within 1.0% of the planned values for all targets and OARs. The corresponding gamma passing rates remained above 90% for all OARs and for all but two PTVs. Limiting hysteresis to 0.5 degree ensured that all metrics stayed within tolerance.

Biomedical Physics & Engineering Express
Good health and well-being
Openalex Percentile: Top 7%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.