Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale

Introduction: Transoesophageal echocardiography (TOE) is claimed to be the investigation of choice for detecting a persistent foramen ovale (PFO) with almost 100% diagnostic accuracy. If true, TOE would detect all large/clinically significant PFOs. Methods: Retrospective analysis to determine the sensitivity of TOE for detection of clinically significant PFOs. Patients were from a consecutive series of 150 patients who had transcatheter closure of a PFO following events attributed to paradoxical embolism (decompression sickness or stroke). In each patient, transthoracic echocardiogram with bubble contrast showed a clinically significant atrial right-to-left shunt. The data reported are from the sub-group of the 150 patients with a clinically significant PFO who also had a TOE performed in other hospitals. Results: Twenty seven of 150 consecutive patients had a total of 31 TOEs performed at 22 United Kingdom regional cardiac centres. TOE failed to detect a PFO in 17 of the 27 patients. Four patients had a TOE on two separate occasions and in each case both of the TOEs failed to show a PFO. TOE gave a false negative test in 21 of 31 investigations (sensitivity 32%). The mean PFO diameter was 9.4 mm (median 9 mm, range 5-16 mm) in the 21 patients in whom balloon sizing was performed and 9.8 mm (median 10 mm, range 5-16 mm) in the 13 patients in whom balloon sizing was performed and a TOE failed to show a PFO. Conclusions: These finding demonstrate that the precision of TOE for detecting a PFO in real world clinical practice is considerably lower than generally believed.

Authors

Institutions

Publication Details

Journal
Diving and Hyperbaric Medicine Journal
Published
2026-06-17
DOI
https://doi.org/10.28920/dhm56.2.148-153
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale

Kevin Walsh, Peter Wilmshurst, W Lindsay Morrison, Matthew Pearson
Diving and Hyperbaric Medicine Journal
Cardiovascular and Diving-Related Complications
article

Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale

Kevin Walsh, Peter Wilmshurst, W Lindsay Morrison, Matthew Pearson
article en

Abstract

Introduction: Transoesophageal echocardiography (TOE) is claimed to be the investigation of choice for detecting a persistent foramen ovale (PFO) with almost 100% diagnostic accuracy. If true, TOE would detect all large/clinically significant PFOs. Methods: Retrospective analysis to determine the sensitivity of TOE for detection of clinically significant PFOs. Patients were from a consecutive series of 150 patients who had transcatheter closure of a PFO following events attributed to paradoxical embolism (decompression sickness or stroke). In each patient, transthoracic echocardiogram with bubble contrast showed a clinically significant atrial right-to-left shunt. The data reported are from the sub-group of the 150 patients with a clinically significant PFO who also had a TOE performed in other hospitals. Results: Twenty seven of 150 consecutive patients had a total of 31 TOEs performed at 22 United Kingdom regional cardiac centres. TOE failed to detect a PFO in 17 of the 27 patients. Four patients had a TOE on two separate occasions and in each case both of the TOEs failed to show a PFO. TOE gave a false negative test in 21 of 31 investigations (sensitivity 32%). The mean PFO diameter was 9.4 mm (median 9 mm, range 5-16 mm) in the 21 patients in whom balloon sizing was performed and 9.8 mm (median 10 mm, range 5-16 mm) in the 13 patients in whom balloon sizing was performed and a TOE failed to show a PFO. Conclusions: These finding demonstrate that the precision of TOE for detecting a PFO in real world clinical practice is considerably lower than generally believed.

Diving and Hyperbaric Medicine JournalVol. 56(2)
University of Liverpool (GB), General Medical Council (GB), Liverpool Heart and Chest Hospital (GB), Our Lady's Hospital (IE), Shrewsbury and Telford Hospital NHS Trust (GB)
Good health and well-being
Openalex Percentile: Top 10%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.