Preclinical evaluation of a fluorine-18-labeled indocyanine green analog for PET imaging of hepatic function

Accurate assessment of liver function and biliary excretion is a key aspect in the medical and surgical management of various liver conditions. Dynamic nuclear imaging techniques such as PET (positron emission tomography) offer the potential to directly quantify hepatic clearance and hepatobiliary function. Indocyanine green (ICG) is a fluorescent dye that is used to indirectly evaluate liver function via its plasma clearance, but its optical properties preclude deep tissue imaging. Here, we report the synthesis and preclinical evaluation of a novel fluorine-18 labeled ICG derivative ([ 18 F]SFB-ICG; SFB = N -succinimidyl-4-[ 18 F]fluorobenzoate) as a potential PET radiotracer for noninvasive assessment of hepatobiliary function. ICG was successfully labeled with 18 F: The product was obtained in high chemical and radionuclidic purity, albeit in relatively low yield (0.25–1.0%, non-decay-corrected). PET imaging demonstrated rapid hepatic uptake with a peak standardized uptake value (SUV) of 8.6 ± 0.8 at 20 min post-injection. The tracer exhibited prompt biliary excretion as demonstrated by a gallbladder SUV of 22.3 ± 1.4 at 45 min post-injection. Time–activity curves confirmed hepatic clearance similar to unlabeled ICG. At 4 h PI, the SUVs of selected organs were: liver 4.7 ± 0.5; lungs 0.15 ± 0.02; small intestine 3.68 ± 0.76; spleen 2.25 ± 0.88; large intestine 4.9 ± 1.7. Renal uptake and clearance was minimal. The whole blood SUV at 1 and 4 h post-injection was 0.47 ± 0.04 and 0.20 ± 0.02, respectively. No overt adverse effects were observed during the 4-h study period. This study presents [ 18 F]SFB-ICG as a novel PET tracer for real-time, quantitative assessment of liver function and biliary clearance in vivo. The tracer exhibits favorable pharmacokinetics, high liver specificity, and excellent correlation with established hepatobiliary physiology. Thus, 18 F-SFB-ICG represents a lead compound that warrants further development—including yield optimization, stability and toxicity characterization, and evaluation in animal models of liver disease—for potential applications in hepatic functional imaging, surgical planning, characterization of liver masses, and assessment of biliary pathology.

Authors

Institutions

Publication Details

Journal
EJNMMI Radiopharmacy and Chemistry
Published
2026-06-16
DOI
https://doi.org/10.1186/s41181-026-00464-w
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preclinical evaluation of a fluorine-18-labeled indocyanine green analog for PET imaging of hepatic function

Khashayar Vakili, Alan Packard
EJNMMI Radiopharmacy and Chemistry
Medical Imaging Techniques and Applications
article

Preclinical evaluation of a fluorine-18-labeled indocyanine green analog for PET imaging of hepatic function

Khashayar Vakili, Alan Packard
article en

Abstract

Accurate assessment of liver function and biliary excretion is a key aspect in the medical and surgical management of various liver conditions. Dynamic nuclear imaging techniques such as PET (positron emission tomography) offer the potential to directly quantify hepatic clearance and hepatobiliary function. Indocyanine green (ICG) is a fluorescent dye that is used to indirectly evaluate liver function via its plasma clearance, but its optical properties preclude deep tissue imaging. Here, we report the synthesis and preclinical evaluation of a novel fluorine-18 labeled ICG derivative ([ 18 F]SFB-ICG; SFB = N -succinimidyl-4-[ 18 F]fluorobenzoate) as a potential PET radiotracer for noninvasive assessment of hepatobiliary function. ICG was successfully labeled with 18 F: The product was obtained in high chemical and radionuclidic purity, albeit in relatively low yield (0.25–1.0%, non-decay-corrected). PET imaging demonstrated rapid hepatic uptake with a peak standardized uptake value (SUV) of 8.6 ± 0.8 at 20 min post-injection. The tracer exhibited prompt biliary excretion as demonstrated by a gallbladder SUV of 22.3 ± 1.4 at 45 min post-injection. Time–activity curves confirmed hepatic clearance similar to unlabeled ICG. At 4 h PI, the SUVs of selected organs were: liver 4.7 ± 0.5; lungs 0.15 ± 0.02; small intestine 3.68 ± 0.76; spleen 2.25 ± 0.88; large intestine 4.9 ± 1.7. Renal uptake and clearance was minimal. The whole blood SUV at 1 and 4 h post-injection was 0.47 ± 0.04 and 0.20 ± 0.02, respectively. No overt adverse effects were observed during the 4-h study period. This study presents [ 18 F]SFB-ICG as a novel PET tracer for real-time, quantitative assessment of liver function and biliary clearance in vivo. The tracer exhibits favorable pharmacokinetics, high liver specificity, and excellent correlation with established hepatobiliary physiology. Thus, 18 F-SFB-ICG represents a lead compound that warrants further development—including yield optimization, stability and toxicity characterization, and evaluation in animal models of liver disease—for potential applications in hepatic functional imaging, surgical planning, characterization of liver masses, and assessment of biliary pathology.

EJNMMI Radiopharmacy and Chemistry
Boston Children's Hospital (US), Harvard University (US), Zen Bio (United States) (US)
Boston Children's Hospital
Zero hunger
Openalex Percentile: Top 8%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.