Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation

Pulmonary vein isolation (PVI) is an established rhythm-control therapy for atrial fibrillation (AF), yet the electrophysiological response of post-PVI individuals exposed to hyperbaric environments remains undocumented. Similarly, the in-vivo performance of implantable loop recorders (ILRs) and external patch-based electrocardiographic (ECG) devices under increased ambient pressure has never been reported. We describe the first hyperbaric electrophysiology assessment in a post-PVI diver undergoing both underwater immersion and dry hyperbaric exposure with dual-modality cardiac rhythm monitoring. A 46-year-old experienced diver with successful PVI underwent: a scuba dive to 42 m in a warm water pool, monitored with a marinised 12-lead ECG Holter system; and a stepwise hyperbaric chamber compression to 284 kPa (2.8 atmospheres absolute) in ambient air, with single-lead surface ECG recordings obtained at static pressure plateaus. In both cases, the subject was monitored as well by his ILR. No AF recurrence or other dysrhythmias were detected during either exposure, with stable heart rate trends. The ILR maintained full functional integrity after both the 42 m dive and the 284 kPa chamber compression. The external ECG patch yielded interpretable tracings during static phases. Telemetry failed due to electromagnetic shielding by the steel chamber walls. This case suggests that carefully selected post-PVI individuals may tolerate controlled underwater and hyperbaric exposure without rhythm destabilisation. Both implantable and external monitoring devices preserved operational integrity under moderate hyperbaric conditions, providing a foundation for the emerging field of hyperbaric electrophysiology monitoring and informing fitness-to-dive assessment in post-ablation patients.

Authors

Institutions

Publication Details

Journal
Diving and Hyperbaric Medicine Journal
Published
2026-06-17
DOI
https://doi.org/10.28920/dhm56.2.203-207
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation

Dario Nicosia, Matteo Paganini, Vincenzo Benenati, Luigi Tarsia et al.
Diving and Hyperbaric Medicine Journal
Cardiovascular and Diving-Related Complications
article

Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation

Dario Nicosia, Matteo Paganini, Vincenzo Benenati, Luigi Tarsia, Gerardo Bosco, Silvio Zerbi
article en

Abstract

Pulmonary vein isolation (PVI) is an established rhythm-control therapy for atrial fibrillation (AF), yet the electrophysiological response of post-PVI individuals exposed to hyperbaric environments remains undocumented. Similarly, the in-vivo performance of implantable loop recorders (ILRs) and external patch-based electrocardiographic (ECG) devices under increased ambient pressure has never been reported. We describe the first hyperbaric electrophysiology assessment in a post-PVI diver undergoing both underwater immersion and dry hyperbaric exposure with dual-modality cardiac rhythm monitoring. A 46-year-old experienced diver with successful PVI underwent: a scuba dive to 42 m in a warm water pool, monitored with a marinised 12-lead ECG Holter system; and a stepwise hyperbaric chamber compression to 284 kPa (2.8 atmospheres absolute) in ambient air, with single-lead surface ECG recordings obtained at static pressure plateaus. In both cases, the subject was monitored as well by his ILR. No AF recurrence or other dysrhythmias were detected during either exposure, with stable heart rate trends. The ILR maintained full functional integrity after both the 42 m dive and the 284 kPa chamber compression. The external ECG patch yielded interpretable tracings during static phases. Telemetry failed due to electromagnetic shielding by the steel chamber walls. This case suggests that carefully selected post-PVI individuals may tolerate controlled underwater and hyperbaric exposure without rhythm destabilisation. Both implantable and external monitoring devices preserved operational integrity under moderate hyperbaric conditions, providing a foundation for the emerging field of hyperbaric electrophysiology monitoring and informing fitness-to-dive assessment in post-ablation patients.

Diving and Hyperbaric Medicine JournalVol. 56(2)
University of Chieti-Pescara (IT), Azienda di Rilievo Nazionale ed Alta Specializzazione (IT), Azienda Ospedaliera Universitaria Policlinico "Paolo Giaccone" di Palermo (IT), American Association for the Surgery of Trauma (US)
Life below water
Openalex Percentile: Top 10%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.