Minimally acceptable criteria and required sample size for an accuracy study of non-invasive prenatal testing of sickle cell disease in screen positive women in England: results of a decision tree model

BACKGROUND: The screening pathway for sickle cell disease (SCD) in England starts with a carrier status blood test for the pregnant woman. Following a positive result, the test is offered to the biological father. Where both results are positive, further invasive testing is offered to assess the risk of SCD to the fetus. When the father is unavailable, the timely offer of further testing may be delayed and even missed, leaving the pregnant woman underinformed and limiting reproductive choice. Non-invasive prenatal testing (NIPT) presents an alternative to paternal testing and diagnostic accuracy studies of NIPT in SCD screening are required to inform utility and application. We explored the minimally acceptable sensitivity and specificity to inform such an accuracy study of NIPT. METHODS: A decision tree model was produced to identify the minimally acceptable sensitivity and specificity of NIPT. Stakeholder engagement identified a positive predictive value (PPV) equal to the paternal carrier blood test and two sensitivity/specificity scenarios: Scenario 1 should result in < 10 false negative diagnoses per year; Scenario 2 should result in ≤ 2 false negative diagnoses per year. Subsequently, the minimally acceptable sensitivity and specificity were used to calculate the sample size for a hypothetical accuracy study of NIPT in each scenario. RESULTS: Scenario 1 led to a minimally acceptable sensitivity of 96.0% and specificity of 88.5% and corresponding negative predictive value (NPV) of 99.81%, PPV of 25.51% and accuracy of 88.80%. Utilising an expected prevalence of SCD of 3.94%, the resulting sample size would include 315,824 total pregnancies. Scenario 2 led to a minimally acceptable sensitivity of 99.0% and specificity of 88.0% and corresponding NPV of 99.95%, PPV of 25.29% and accuracy of 88.43%. The resulting sample size would include 65,509 overall pregnancies. CONCLUSIONS: While the sample size calculated for each scenario is unfeasible if considering a prospective cohort study, approaches are presented to achieve realistic sample sizes. Increasing the sensitivity and specificity levels might be considered if this is likely to be achievable based on available studies, albeit limited in volume. Consideration could be given to study design mitigations that are consistent with guidance on accuracy studies in low prevalence settings.

Authors

Institutions

Publication Details

Journal
Diagnostic and Prognostic Research
Published
2026-06-15
DOI
https://doi.org/10.1186/s41512-025-00192-w
Citations
1
Primary Topic
Hemoglobinopathies and Related Disorders
Type
article
Field-Weighted Citation Impact
11.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Minimally acceptable criteria and required sample size for an accuracy study of non-invasive prenatal testing of sickle cell disease in screen positive women in England: results of a decision tree model

Amanda Hogan, Silvia Lombardo, Farah Seedat, Mariska Leeflang et al.
1 citations
Diagnostic and Prognostic Research
Hemoglobinopathies and Related Disorders
11.57
article

Minimally acceptable criteria and required sample size for an accuracy study of non-invasive prenatal testing of sickle cell disease in screen positive women in England: results of a decision tree model

Amanda Hogan, Silvia Lombardo, Farah Seedat, Mariska Leeflang, Vittoria Vardanega, Benjamin Ruban‐Fell, Dr Yvonne Daniel, Ania Bobrowska, Anna Schuh, Kathy Mann, James A. Doorbar, John Marshall
article en
1 citations

Abstract

BACKGROUND: The screening pathway for sickle cell disease (SCD) in England starts with a carrier status blood test for the pregnant woman. Following a positive result, the test is offered to the biological father. Where both results are positive, further invasive testing is offered to assess the risk of SCD to the fetus. When the father is unavailable, the timely offer of further testing may be delayed and even missed, leaving the pregnant woman underinformed and limiting reproductive choice. Non-invasive prenatal testing (NIPT) presents an alternative to paternal testing and diagnostic accuracy studies of NIPT in SCD screening are required to inform utility and application. We explored the minimally acceptable sensitivity and specificity to inform such an accuracy study of NIPT. METHODS: A decision tree model was produced to identify the minimally acceptable sensitivity and specificity of NIPT. Stakeholder engagement identified a positive predictive value (PPV) equal to the paternal carrier blood test and two sensitivity/specificity scenarios: Scenario 1 should result in < 10 false negative diagnoses per year; Scenario 2 should result in ≤ 2 false negative diagnoses per year. Subsequently, the minimally acceptable sensitivity and specificity were used to calculate the sample size for a hypothetical accuracy study of NIPT in each scenario. RESULTS: Scenario 1 led to a minimally acceptable sensitivity of 96.0% and specificity of 88.5% and corresponding negative predictive value (NPV) of 99.81%, PPV of 25.51% and accuracy of 88.80%. Utilising an expected prevalence of SCD of 3.94%, the resulting sample size would include 315,824 total pregnancies. Scenario 2 led to a minimally acceptable sensitivity of 99.0% and specificity of 88.0% and corresponding NPV of 99.95%, PPV of 25.29% and accuracy of 88.43%. The resulting sample size would include 65,509 overall pregnancies. CONCLUSIONS: While the sample size calculated for each scenario is unfeasible if considering a prospective cohort study, approaches are presented to achieve realistic sample sizes. Increasing the sensitivity and specificity levels might be considered if this is likely to be achievable based on available studies, albeit limited in volume. Consideration could be given to study design mitigations that are consistent with guidance on accuracy studies in low prevalence settings.

Diagnostic and Prognostic ResearchVol. 10(1)
Department of Health and Social Care (GB), St Thomas' Hospital (GB), St George's, University of London (GB), Multiple Sclerosis International Federation (GB), Cambridge University Hospitals NHS Foundation Trust (GB), Public Health England (GB), University of Oxford (GB), St. Thomas Hospital (CA), Amsterdam University Medical Centers (NL), Costello Medical Consulting (United Kingdom) (GB), University of Amsterdam (NL)
Gender equality
Openalex Percentile: Top 1%
Hemoglobinopathies and Related Disorders
11.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.