Can an Artificial Intelligence Application Raise Awareness of Dislocation Risk After Total Hip Arthroplasty?

Background Dislocation after total hip arthroplasty (THA) is a devastating complication. The hip-spine relationship is a significant contributor to hip instability and dislocation after THA but is predominantly evaluated with static radiographs, limiting its utility. This study evaluated a novel artificial intelligence (AI)-based application for real-time analysis of hip-spine motion prior to THA to dynamically evaluate patients' hip-spine stiffness in real-time prior to THA. Methods Preoperative hip and spine flexibility were assessed using an AI application that recorded patients performing sit-to-stand, forward flexion, and standing posture maneuvers. Minimum and maximum neck, spine, trunk, and knee angles were measured preoperatively. Preoperative radiographs were also evaluated for spinal stiffness indicators. Acetabular component abduction and anteversion angles were measured to confirm adequate positioning. Results Nineteen patients underwent THA via an anterior-based muscle-sparing approach with a minimum 12-month follow-up. The mean preoperative forward flexion trunk angle was 95.7° ± 14.4° (25th percentile: ≤87.2°). During sit-to-stand, mean maximum and minimum spine angles were 38.3° ± 13.3° (25th percentile: ≤27.6°) and 5.1° ± 5.9° (75th percentile: ≥6.2°), respectively. Fifteen patients (78.9%) received 36-mm femoral heads. Mean abduction and anteversion was 43.9° and 26.4°, respectively. No postoperative hip dislocations occurred. Conclusions This AI-based hip joint assessment tool may serve as a clinic-based tool to evaluate the hip-spine relationship as a dynamic predictor of dislocation risk. It may offer greater accuracy than static radiographs, which cannot comprehensively capture real-time functional movements. This tool may improve surgical planning, particularly in higher-risk patients. Larger studies are needed to validate its predictivity and clinical utility.

Authors

Institutions

Publication Details

Journal
Arthroplasty Today
Published
2026-06-14
DOI
https://doi.org/10.1016/j.artd.2026.102070
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can an Artificial Intelligence Application Raise Awareness of Dislocation Risk After Total Hip Arthroplasty?

John AR. Ferrara, Jaden S. Queen, Jeffrey A. Geller
Arthroplasty Today
Orthopaedic implants and arthroplasty
article

Can an Artificial Intelligence Application Raise Awareness of Dislocation Risk After Total Hip Arthroplasty?

John AR. Ferrara, Jaden S. Queen, Jeffrey A. Geller
article en

Abstract

Background Dislocation after total hip arthroplasty (THA) is a devastating complication. The hip-spine relationship is a significant contributor to hip instability and dislocation after THA but is predominantly evaluated with static radiographs, limiting its utility. This study evaluated a novel artificial intelligence (AI)-based application for real-time analysis of hip-spine motion prior to THA to dynamically evaluate patients' hip-spine stiffness in real-time prior to THA. Methods Preoperative hip and spine flexibility were assessed using an AI application that recorded patients performing sit-to-stand, forward flexion, and standing posture maneuvers. Minimum and maximum neck, spine, trunk, and knee angles were measured preoperatively. Preoperative radiographs were also evaluated for spinal stiffness indicators. Acetabular component abduction and anteversion angles were measured to confirm adequate positioning. Results Nineteen patients underwent THA via an anterior-based muscle-sparing approach with a minimum 12-month follow-up. The mean preoperative forward flexion trunk angle was 95.7° ± 14.4° (25th percentile: ≤87.2°). During sit-to-stand, mean maximum and minimum spine angles were 38.3° ± 13.3° (25th percentile: ≤27.6°) and 5.1° ± 5.9° (75th percentile: ≥6.2°), respectively. Fifteen patients (78.9%) received 36-mm femoral heads. Mean abduction and anteversion was 43.9° and 26.4°, respectively. No postoperative hip dislocations occurred. Conclusions This AI-based hip joint assessment tool may serve as a clinic-based tool to evaluate the hip-spine relationship as a dynamic predictor of dislocation risk. It may offer greater accuracy than static radiographs, which cannot comprehensively capture real-time functional movements. This tool may improve surgical planning, particularly in higher-risk patients. Larger studies are needed to validate its predictivity and clinical utility.

Arthroplasty TodayVol. 40
Columbia University Irving Medical Center (US)
Reduced inequalities
Openalex Percentile: Top 6%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Can an Artificial Intelligence Application Raise Awareness of Dislocation Risk After Total Hip Arthroplasty? — John AR. Ferrara, Jaden S. Queen, et al. · Arthroplasty Today (2026) | TGRS Research Map | TGRS