Hand Rehabilitation Dynamic Splint with Variable Force via Pneumatic Artificial Muscle Actuators

PURPOSE: Dynamic hand splints are rehabilitation orthoses equipped with elastic bands/springs that provide passive resistance to finger movements. To enable real-time controllability of rehabilitative exercises and potentially improve therapeutic outcomes, it would be advantageous to replace the elastic components with soft actuators, enabling finger movements to be exercised against controllable loads. The ideal soft actuators for dynamic hand splints should generate large displacements at moderate forces, have a compact size and low specific weight, and be electrically safe. METHODS: Here, we describe a dynamic splint embedded with soft pneumatic actuators functioning as "inverse artificial muscles", which elongate when pressurised, reducing the force that resists finger flexions. A prototype system was assembled using off-the-shelf materials. An actuator was fabricated and mounted on a forearm brace, connecting one extremity to a finger via a tendon and the other one to an onboard load cell, to monitor the force exerted during finger motions. The system was tested via two psychophysical tests. RESULTS: A dynamic psychophysical test on perceptual differences in force demonstrated that subjects were able to reliably perceive force variations, with a sensitivity (slope of the psychometric curve) of ~ 110%/bar at 50% probability. In a static psychophysical test with a fully flexed finger, the maximum average force was ~ 5.2 N at 0 bar, whilst the minimum average force when subjects reported no perception of force, by progressively increasing the pressure, was as low as ~ 0.7 N at 3 bar, indicating good accuracy of the system. CONCLUSION: The developed active splint has the potential to enable dynamically controllable hand rehabilitation tasks.

Authors

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2026-06-14
DOI
https://doi.org/10.1007/s10439-026-04233-3
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hand Rehabilitation Dynamic Splint with Variable Force via Pneumatic Artificial Muscle Actuators

Federico Carpi, Mattia Dimitri, V. Potnik, G. Frediani
Annals of Biomedical Engineering
Prosthetics and Rehabilitation Robotics
article

Hand Rehabilitation Dynamic Splint with Variable Force via Pneumatic Artificial Muscle Actuators

Federico Carpi, Mattia Dimitri, V. Potnik, G. Frediani
article en

Abstract

PURPOSE: Dynamic hand splints are rehabilitation orthoses equipped with elastic bands/springs that provide passive resistance to finger movements. To enable real-time controllability of rehabilitative exercises and potentially improve therapeutic outcomes, it would be advantageous to replace the elastic components with soft actuators, enabling finger movements to be exercised against controllable loads. The ideal soft actuators for dynamic hand splints should generate large displacements at moderate forces, have a compact size and low specific weight, and be electrically safe. METHODS: Here, we describe a dynamic splint embedded with soft pneumatic actuators functioning as "inverse artificial muscles", which elongate when pressurised, reducing the force that resists finger flexions. A prototype system was assembled using off-the-shelf materials. An actuator was fabricated and mounted on a forearm brace, connecting one extremity to a finger via a tendon and the other one to an onboard load cell, to monitor the force exerted during finger motions. The system was tested via two psychophysical tests. RESULTS: A dynamic psychophysical test on perceptual differences in force demonstrated that subjects were able to reliably perceive force variations, with a sensitivity (slope of the psychometric curve) of ~ 110%/bar at 50% probability. In a static psychophysical test with a fully flexed finger, the maximum average force was ~ 5.2 N at 0 bar, whilst the minimum average force when subjects reported no perception of force, by progressively increasing the pressure, was as low as ~ 0.7 N at 3 bar, indicating good accuracy of the system. CONCLUSION: The developed active splint has the potential to enable dynamically controllable hand rehabilitation tasks.

Annals of Biomedical Engineering
Don Carlo Gnocchi Foundation (IT), University of Florence (IT)
European Commission, Ministero dell’Istruzione, dell’Università e della Ricerca, Università degli Studi di Firenze, Fondazione Cassa di Risparmio di Firenze, Ministero dell'Università e della Ricerca, H2020 Marie Skłodowska-Curie Actions
Good health and well-being
Openalex Percentile: Top 11%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.