Comparison of bi- and tri-component approaches for the analysis of short-T2* tissues in the presence of fat: application to the Achilles tendon
Abstract Objective To evaluate how data acquisition and post-processing choices influence ultrashort echo time (UTE)–based characterization of the short-T 2 * compositional structure of the Achilles tendon. Methods Ten healthy volunteers (33.3 ± 6.9 years) underwent Achilles tendon MRI using a multi-echo, time-interleaved UTE sequence. T 2 * data were analyzed with and without fat suppression using two models: (i) a bi-component decay with two water pools and (ii) a tri-component decay including two water components and one fat component. The effect of magnitude versus complex fitting on compositional estimates was also assessed. Three Achilles tendon regions were analyzed: insertion (INS), mid-portion (MID), and muscle–tendon junction (MTJ). Results Estimated short vs. long T 2 * components differed significantly depending on the use of fat suppression ( p < 0.001 for all tendon regions) and fitting method (magnitude vs. complex) ( p INS = 0.002, p MID < 0.001, p MTJ < 0.001). T 2 * time constants were comparatively stable, particularly in the MID part ( p > 0.05). The fitting method affected short T 2 * component in the MTJ ( p MTJ = 0.032) and long T 2 * component in the INS and MTJ ( p INS = 0.025, p MTJ < 0.017). Discussion Non-fat-suppressed vs. fat-suppressed (FS) strategy and fitting approach substantially affect bi-component T 2 * quantification of the Achilles tendon, limiting comparability of UTE-based metrics. Tri-component modeling provides a more realistic description of tendon signal and may improve sensitivity to pathological changes. Further studies in patients are needed.
Authors
- Martin Kojan (ORCID: https://orcid.org/0000-0002-5403-6135)
- Siegfried Trattnig (ORCID: https://orcid.org/0000-0003-1623-3303)
- Vladimír Juráš (ORCID: https://orcid.org/0000-0002-4026-5922)
- Veronika Janáčová (ORCID: https://orcid.org/0000-0003-2138-1220)
- Peter Latta (ORCID: https://orcid.org/0000-0002-0579-8635)
- Aneta Malá (ORCID: https://orcid.org/0000-0001-9456-3207)
- Ľubomír Vojtíšek (ORCID: https://orcid.org/0000-0002-4027-6568)
- Zenon Starčuk (ORCID: https://orcid.org/0000-0002-1218-0585)
Institutions
- Central European Institute of Technology (CZ)
- Czech Academy of Sciences, Institute of Scientific Instruments (CZ)
- Center For Biomarker Research In Medicine (AT)
- Medical University of Vienna (AT)
Publication Details
- Journal
- Magnetic Resonance Materials in Physics Biology and Medicine
- Published
- 2026-06-13
- DOI
- https://doi.org/10.1007/s10334-026-01383-2
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00