Comparison of bi- and tri-component approaches for the analysis of short-T2* tissues in the presence of fat: application to the Achilles tendon

Abstract Objective To evaluate how data acquisition and post-processing choices influence ultrashort echo time (UTE)–based characterization of the short-T 2 * compositional structure of the Achilles tendon. Methods Ten healthy volunteers (33.3 ± 6.9 years) underwent Achilles tendon MRI using a multi-echo, time-interleaved UTE sequence. T 2 * data were analyzed with and without fat suppression using two models: (i) a bi-component decay with two water pools and (ii) a tri-component decay including two water components and one fat component. The effect of magnitude versus complex fitting on compositional estimates was also assessed. Three Achilles tendon regions were analyzed: insertion (INS), mid-portion (MID), and muscle–tendon junction (MTJ). Results Estimated short vs. long T 2 * components differed significantly depending on the use of fat suppression ( p < 0.001 for all tendon regions) and fitting method (magnitude vs. complex) ( p INS = 0.002, p MID < 0.001, p MTJ < 0.001). T 2 * time constants were comparatively stable, particularly in the MID part ( p > 0.05). The fitting method affected short T 2 * component in the MTJ ( p MTJ = 0.032) and long T 2 * component in the INS and MTJ ( p INS = 0.025, p MTJ < 0.017). Discussion Non-fat-suppressed vs. fat-suppressed (FS) strategy and fitting approach substantially affect bi-component T 2 * quantification of the Achilles tendon, limiting comparability of UTE-based metrics. Tri-component modeling provides a more realistic description of tendon signal and may improve sensitivity to pathological changes. Further studies in patients are needed.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance Materials in Physics Biology and Medicine
Published
2026-06-13
DOI
https://doi.org/10.1007/s10334-026-01383-2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of bi- and tri-component approaches for the analysis of short-T2* tissues in the presence of fat: application to the Achilles tendon

Martin Kojan, Siegfried Trattnig, Vladimír Juráš, Veronika Janáčová et al.
Magnetic Resonance Materials in Physics Biology and Medicine
Advanced MRI Techniques and Applications
article

Comparison of bi- and tri-component approaches for the analysis of short-T2* tissues in the presence of fat: application to the Achilles tendon

Martin Kojan, Siegfried Trattnig, Vladimír Juráš, Veronika Janáčová, Peter Latta, Aneta Malá, Ľubomír Vojtíšek, Zenon Starčuk
article en

Abstract

Abstract Objective To evaluate how data acquisition and post-processing choices influence ultrashort echo time (UTE)–based characterization of the short-T 2 * compositional structure of the Achilles tendon. Methods Ten healthy volunteers (33.3 ± 6.9 years) underwent Achilles tendon MRI using a multi-echo, time-interleaved UTE sequence. T 2 * data were analyzed with and without fat suppression using two models: (i) a bi-component decay with two water pools and (ii) a tri-component decay including two water components and one fat component. The effect of magnitude versus complex fitting on compositional estimates was also assessed. Three Achilles tendon regions were analyzed: insertion (INS), mid-portion (MID), and muscle–tendon junction (MTJ). Results Estimated short vs. long T 2 * components differed significantly depending on the use of fat suppression ( p < 0.001 for all tendon regions) and fitting method (magnitude vs. complex) ( p INS = 0.002, p MID < 0.001, p MTJ < 0.001). T 2 * time constants were comparatively stable, particularly in the MID part ( p > 0.05). The fitting method affected short T 2 * component in the MTJ ( p MTJ = 0.032) and long T 2 * component in the INS and MTJ ( p INS = 0.025, p MTJ < 0.017). Discussion Non-fat-suppressed vs. fat-suppressed (FS) strategy and fitting approach substantially affect bi-component T 2 * quantification of the Achilles tendon, limiting comparability of UTE-based metrics. Tri-component modeling provides a more realistic description of tendon signal and may improve sensitivity to pathological changes. Further studies in patients are needed.

Magnetic Resonance Materials in Physics Biology and Medicine
Central European Institute of Technology (CZ), Czech Academy of Sciences, Institute of Scientific Instruments (CZ), Center For Biomarker Research In Medicine (AT), Medical University of Vienna (AT)
Clean water and sanitation
Openalex Percentile: Top 5%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.