Perioperative management in a patient with congenital factor VII deficiency following mechanical valve replacement: a case report

Congenital factor VII deficiency (CFVIID) is a rare hemorrhagic disorder which elevates perioperative bleeding risks. Mechanical prosthesis mandates lifelong anticoagulation, while international normalized ratio (INR) of CFVIID deviates significantly from the normal range which could not accurately reflect the real anticoagulation. Perioperative management for CFVIID patients undergoing mechanical valve replacement are highly challenging, with no clinical guidelines currently available. We reported a 59-year-old CFVIID patient undergoing mechanical valve replacement. Perioperative recombinant activated factor VII (rFVIIa) replacement secured hemostasis. After postoperative cerebral thrombosis, anticoagulation of warfarin was initiated and guided by factor Ⅱ/Ⅹ activity (30–45%) rather than INR. No bleeding or recurrent thrombosis was observed. Perioperative rFVIIa replacement guarantees hemostatic safety for cardiac surgery. Lifelong warfarin anticoagulation is essential for CFVIID patient with mechanical prosthesis. Monitoring factor Ⅱ/Ⅹ activity instead of INR can balance bleeding and thrombosis risks for such cases.

Authors

Institutions

Publication Details

Journal
Thrombosis Journal
Published
2026-06-13
DOI
https://doi.org/10.1186/s12959-026-00886-1
Primary Topic
Hemophilia Treatment and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perioperative management in a patient with congenital factor VII deficiency following mechanical valve replacement: a case report

Tucheng Sun, Xiaokang Luo, Xue Yang, Xinjian Yan
Thrombosis Journal
Hemophilia Treatment and Research
article

Perioperative management in a patient with congenital factor VII deficiency following mechanical valve replacement: a case report

Tucheng Sun, Xiaokang Luo, Xue Yang, Xinjian Yan
article en

Abstract

Congenital factor VII deficiency (CFVIID) is a rare hemorrhagic disorder which elevates perioperative bleeding risks. Mechanical prosthesis mandates lifelong anticoagulation, while international normalized ratio (INR) of CFVIID deviates significantly from the normal range which could not accurately reflect the real anticoagulation. Perioperative management for CFVIID patients undergoing mechanical valve replacement are highly challenging, with no clinical guidelines currently available. We reported a 59-year-old CFVIID patient undergoing mechanical valve replacement. Perioperative recombinant activated factor VII (rFVIIa) replacement secured hemostasis. After postoperative cerebral thrombosis, anticoagulation of warfarin was initiated and guided by factor Ⅱ/Ⅹ activity (30–45%) rather than INR. No bleeding or recurrent thrombosis was observed. Perioperative rFVIIa replacement guarantees hemostatic safety for cardiac surgery. Lifelong warfarin anticoagulation is essential for CFVIID patient with mechanical prosthesis. Monitoring factor Ⅱ/Ⅹ activity instead of INR can balance bleeding and thrombosis risks for such cases.

Thrombosis Journal
Sun Yat-sen University (CN), Fudan University (CN), Beijing Academy of Artificial Intelligence (CN), Zhongshan Hospital (CN), The First Affiliated Hospital, Sun Yat-sen University (CN), Guangdong Academy of Medical Sciences (CN), Guangdong Provincial People's Hospital (CN)
Partnerships for the goals
Openalex Percentile: Top 6%
Hemophilia Treatment and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Perioperative management in a patient with congenital factor VII deficiency following mechanical valve replacement: a case report — Tucheng Sun, Xiaokang Luo, et al. · Thrombosis Journal (2026) | TGRS Research Map | TGRS