Development and Validation of an ELISA Method for Quantification of HuB01 in Fermentation Products

BACKGROUND: The antibodies (including 7C4, 8D1) are neutralizing antibodies specifically targeting the protein RBD, a key core of the combination with angiotensin-converting enzyme 2 (ACE2). In order to measure HuB01 in fermentation products accurately, a bioanalytical method was needed, which should have high selectivity and be free from interference by 501Y.V2. METHODS AND RESULTS: To quantify HuB01 in fermentation products, an indirect ELISA was developed and validated, utilizing anti-idiotypic monoclonal antibodies for both capture and detection. The assay demonstrates high sensitivity, with a lower limit of quantification set at 3.906 ng/mL, a wide dynamic range spanning 3906-125 ng/mL for HuB01, and outstanding precision and accuracy. CONCLUSION: A sensitive and selective method for measuring HuB01 in fermentation products has been developed and validated by us. Currently, this assay is applied in the quality control of the production process.

Authors

Institutions

Publication Details

Journal
Biotechnology and Applied Biochemistry
Published
2026-06-12
DOI
https://doi.org/10.1002/bab.70183
Primary Topic
Protein Hydrolysis and Bioactive Peptides
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of an ELISA Method for Quantification of HuB01 in Fermentation Products

Yun Liu, Zengmin Yang, Yao Zhang, Yuying Liu et al.
Biotechnology and Applied Biochemistry
Protein Hydrolysis and Bioactive Peptides
article

Development and Validation of an ELISA Method for Quantification of HuB01 in Fermentation Products

Yun Liu, Zengmin Yang, Yao Zhang, Yuying Liu, Xinyu Yu, Yongjiang Liu, Ling Li, Dan Chen, Haijiang Zhang
article en

Abstract

BACKGROUND: The antibodies (including 7C4, 8D1) are neutralizing antibodies specifically targeting the protein RBD, a key core of the combination with angiotensin-converting enzyme 2 (ACE2). In order to measure HuB01 in fermentation products accurately, a bioanalytical method was needed, which should have high selectivity and be free from interference by 501Y.V2. METHODS AND RESULTS: To quantify HuB01 in fermentation products, an indirect ELISA was developed and validated, utilizing anti-idiotypic monoclonal antibodies for both capture and detection. The assay demonstrates high sensitivity, with a lower limit of quantification set at 3.906 ng/mL, a wide dynamic range spanning 3906-125 ng/mL for HuB01, and outstanding precision and accuracy. CONCLUSION: A sensitive and selective method for measuring HuB01 in fermentation products has been developed and validated by us. Currently, this assay is applied in the quality control of the production process.

Biotechnology and Applied Biochemistry
Beijing VDJBio (China) (CN)
Openalex Percentile: Top 9%
Protein Hydrolysis and Bioactive Peptides
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.