Occupational radiation doses in CT-guided interventions: A multicentre evaluation with special emphasis on lung biopsies and eye lens doses

Purpose This study aimed to investigate eye lens and whole-body radiation doses received by interventional radiologists during CT-guided procedures, with a particular focus on lung biopsies. Methods Simultaneous measurements of eye lens dose equivalent H p (3), deep-dose equivalent H p (10), and shallow-dose equivalent H p (0.07) were conducted under clinical conditions during CT-guided procedures in five Finnish hospitals during four separate four-week measurement periods. H p (3) was measured using EYE-D thermoluminescent dosimeters, while H p (10) and H p (0.07) were recorded using DIS-1 dosimeters. The H p (3)/H p (10) and H p (3)/H p (0.07) ratios, and H p (3) to dose-length product (DLP) were analysed to assess whether routinely measured quantities can provide a rough indication of eye lens dose in CT-guided procedures. The doses per CT procedure were analysed for all aforementioned dose equivalents to evaluate the annual exposures. Dosimeter calibration and quality control were performed at a secondary standard dosimetry laboratory. Staff positioning, radiation protection practices, and procedural variables were explored in relation to differences in observed exposure levels across hospitals and procedures. Results and conclusions Occupational radiation exposure during CT-guided procedures were generally negligible when appropriate radiological practices and protective equipment were used. One hospital showed significantly higher dose values due to the primary use of fluoroscopy and absence of a lead glass screen. Despite this aberrant result, exposure levels remained below annual occupational dose limits in all hospitals. Routinely measured H p (10) and H p (0.07) showed a strong relationship with H p (3) in the measurable dose data, suggesting that they may provide a rough indication of the order of magnitude of eye lens dose.

Authors

Institutions

Publication Details

Journal
Physica Medica
Published
2026-06-13
DOI
https://doi.org/10.1016/j.ejmp.2026.105833
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occupational radiation doses in CT-guided interventions: A multicentre evaluation with special emphasis on lung biopsies and eye lens doses

A. Pekkarinen, Touko Kaasalainen, Mika Kortesniemi, Hemmo Hartikainen
Physica Medica
Radiation Dose and Imaging
article

Occupational radiation doses in CT-guided interventions: A multicentre evaluation with special emphasis on lung biopsies and eye lens doses

A. Pekkarinen, Touko Kaasalainen, Mika Kortesniemi, Hemmo Hartikainen
article en

Abstract

Purpose This study aimed to investigate eye lens and whole-body radiation doses received by interventional radiologists during CT-guided procedures, with a particular focus on lung biopsies. Methods Simultaneous measurements of eye lens dose equivalent H p (3), deep-dose equivalent H p (10), and shallow-dose equivalent H p (0.07) were conducted under clinical conditions during CT-guided procedures in five Finnish hospitals during four separate four-week measurement periods. H p (3) was measured using EYE-D thermoluminescent dosimeters, while H p (10) and H p (0.07) were recorded using DIS-1 dosimeters. The H p (3)/H p (10) and H p (3)/H p (0.07) ratios, and H p (3) to dose-length product (DLP) were analysed to assess whether routinely measured quantities can provide a rough indication of eye lens dose in CT-guided procedures. The doses per CT procedure were analysed for all aforementioned dose equivalents to evaluate the annual exposures. Dosimeter calibration and quality control were performed at a secondary standard dosimetry laboratory. Staff positioning, radiation protection practices, and procedural variables were explored in relation to differences in observed exposure levels across hospitals and procedures. Results and conclusions Occupational radiation exposure during CT-guided procedures were generally negligible when appropriate radiological practices and protective equipment were used. One hospital showed significantly higher dose values due to the primary use of fluoroscopy and absence of a lead glass screen. Despite this aberrant result, exposure levels remained below annual occupational dose limits in all hospitals. Routinely measured H p (10) and H p (0.07) showed a strong relationship with H p (3) in the measurable dose data, suggesting that they may provide a rough indication of the order of magnitude of eye lens dose.

Physica MedicaVol. 148
University of Turku (FI), Helsinki University Hospital (FI), Kymenlaakson keskussairaala (FI)
Openalex Percentile: Top 5%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.