Accurate alpha-particle stopping power measurements in graphenic carbon foils and their application to high-precision, non-destructive areal density determination
A precise, non-destructive method for determining the areal density of thin graphenic carbon (GC) foils via alpha-particle energy loss is presented. Two types of GC foils - sourced from KETEK GmbH and Applied Nanotech Inc. - were investigated using a three-isotope mixed alpha source emitting particles in the 5.0-5.8 [Formula: see text] range. Both foils have similar nominal areal densities of approximately [Formula: see text], but differ slightly in chemical composition and microstructure. High-resolution alpha spectroscopy yielded energy-loss measurements with relative uncertainties below 1%. The uncertainty of the extracted areal densities and stopping powers is dominated by the determination of foil mass, area and composition metrology, rather than by the alpha-energy-loss measurement itself. Experimental stopping powers were obtained by combining the measured energy loss with independently determined foil masses and areas, and were compared with established stopping-power models. A modified Bethe formalism incorporating Barkas and Bloch corrections, together with an empirically adjusted mean excitation energy [Formula: see text], provided the most consistent description of the data across the investigated energy range. The resulting values were [Formula: see text] for the KETEK foil and [Formula: see text] for the Applied Nanotech foil. The fitted stopping-power curves indicate a systematic difference between the two GC foils, consistent with their differing compositions and microstructures. Because the stopping-power model is calibrated against the same reference foils, however, this interpretation is model-dependent and requires further validation using independently characterised samples. While the method is well suited to thin foils, angular straggling and the non-linear energy dependence of the stopping power may limit its applicability beyond the thin-target approximation. The reported stopping-power data are relevant for benchmarking Monte Carlo simulations and modelling energy deposition in carbon-based materials, with applications in accelerator technology and radiopharmaceutical research. In medical physics, stopping power is closely related to linear energy transfer, which governs the biological effectiveness of alpha-emitting isotopes in targeted therapies.
Authors
- Maxim Saifulin (ORCID: https://orcid.org/0000-0001-9408-9277)
- E. Haettner (ORCID: https://orcid.org/0000-0002-5057-9853)
- C. Scheidenberger (ORCID: https://orcid.org/0000-0003-3409-0350)
- H. Weick (ORCID: https://orcid.org/0000-0003-3672-1961)
- M. Tomut (ORCID: https://orcid.org/0000-0001-7008-624X)
- J. Enders (ORCID: https://orcid.org/0000-0002-8441-378X)
- D. J. Morrissey (ORCID: https://orcid.org/0000-0003-2791-5924)
- H. Geißel (ORCID: https://orcid.org/0000-0002-9656-1819)
- S. Purushothaman (ORCID: https://orcid.org/0000-0003-0526-4913)
- T. Dickel (ORCID: https://orcid.org/0000-0002-5965-8689)
- Konstantina Botsiou
- Jianwei Zhao
Institutions
- GSI Helmholtz Centre for Heavy Ion Research (DE)
- Justus-Liebig-Universität Gießen (DE)
- University of Münster (DE)
- Technische Universität Darmstadt (DE)
- Helmholtz Institute Mainz (DE)
- Facility for Antiproton and Ion Research (DE)
- Beihang University (CN)
- Michigan State University (US)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-06-14
- DOI
- https://doi.org/10.1038/s41598-026-57488-0
- Primary Topic
- X-ray Spectroscopy and Fluorescence Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Technische Universität Darmstadt
- GSI Helmholtzzentrum für Schwerionenforschung