Evaluation of a Novel In Vitro Diagnostic Immunoassay for the Rapid Qualitative Detection of KPC, NDM, OXA-48-like, IMP and VIM Carbapenemases

Background/Objectives: The global spread of carbapenemase-producing Gram-negative bacteria (CP-GNB) represents a major clinical challenge, causing severe hospital-acquired infections with limited treatment options. Accurate and rapid detection is essential for guiding antimicrobial therapy and implementing infection control measures. Lateral flow immunoassays (LFIAs) targeting the five main carbapenemase families are increasingly used in routine diagnostics, and many new commercial assays have recently become available, often without thorough assessment. The continuous evolution of these enzymes under antibiotic pressure requires regular reassessment of assay performance. Methods: In this study, we evaluated the Beright Carba-5 assay (Alltest Biotech, Hangzhou, China) targeting the five main carbapenemases (KPC, NDM, OXA-48-like, IMP, and VIM), on a panel of 77 whole-genome sequenced Gram-negative bacterial (GNB) isolates exhibiting reduced susceptibility to carbapenems. Seventy-three were carbapenemase-producing (CP) GNBs, including six VIM-, 18 OXA-48-, 14 KPC-, 9 NDM-, 8 IMP-, 10 multiple carbapenemase-, and eight non-targeted carbapenemase-producers. Results: The assay was rapid and easy to use, showing 100% (CI: 73.54% to 100%) specificity, with no false positive results. However, overall sensitivity of CP-GNB detection was lower than expected at 63.08% (CI: 50.20% to 74.72%), with numerous false negatives, particularly among IMP and NDM producers, and to a lesser extent, KPC producers. Detection was more reliable for VIM and OXA-48-like variants. Practical limitations, including insufficient buffer supply, reduced the number of tested isolates from the planned 100 to 77. Conclusions: Overall, the Beright assay demonstrated insufficient sensitivity for routine diagnostic use.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-06-12
DOI
https://doi.org/10.3390/diagnostics16121818
Primary Topic
Antibiotic Resistance in Bacteria
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a Novel In Vitro Diagnostic Immunoassay for the Rapid Qualitative Detection of KPC, NDM, OXA-48-like, IMP and VIM Carbapenemases

Saoussen Oueslati, Thierry Naas, Hervé Volland, Zoe Dunne
Diagnostics
Antibiotic Resistance in Bacteria
article

Evaluation of a Novel In Vitro Diagnostic Immunoassay for the Rapid Qualitative Detection of KPC, NDM, OXA-48-like, IMP and VIM Carbapenemases

Saoussen Oueslati, Thierry Naas, Hervé Volland, Zoe Dunne
article en

Abstract

Background/Objectives: The global spread of carbapenemase-producing Gram-negative bacteria (CP-GNB) represents a major clinical challenge, causing severe hospital-acquired infections with limited treatment options. Accurate and rapid detection is essential for guiding antimicrobial therapy and implementing infection control measures. Lateral flow immunoassays (LFIAs) targeting the five main carbapenemase families are increasingly used in routine diagnostics, and many new commercial assays have recently become available, often without thorough assessment. The continuous evolution of these enzymes under antibiotic pressure requires regular reassessment of assay performance. Methods: In this study, we evaluated the Beright Carba-5 assay (Alltest Biotech, Hangzhou, China) targeting the five main carbapenemases (KPC, NDM, OXA-48-like, IMP, and VIM), on a panel of 77 whole-genome sequenced Gram-negative bacterial (GNB) isolates exhibiting reduced susceptibility to carbapenems. Seventy-three were carbapenemase-producing (CP) GNBs, including six VIM-, 18 OXA-48-, 14 KPC-, 9 NDM-, 8 IMP-, 10 multiple carbapenemase-, and eight non-targeted carbapenemase-producers. Results: The assay was rapid and easy to use, showing 100% (CI: 73.54% to 100%) specificity, with no false positive results. However, overall sensitivity of CP-GNB detection was lower than expected at 63.08% (CI: 50.20% to 74.72%), with numerous false negatives, particularly among IMP and NDM producers, and to a lesser extent, KPC producers. Detection was more reliable for VIM and OXA-48-like variants. Practical limitations, including insufficient buffer supply, reduced the number of tested isolates from the planned 100 to 77. Conclusions: Overall, the Beright assay demonstrated insufficient sensitivity for routine diagnostic use.

DiagnosticsVol. 16(12)
Royal College of Surgeons in Ireland (IE), Inserm (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Université Paris-Saclay (FR), Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR), CEA Paris-Saclay (FR), CNR de la Résistance aux Antibiotiques (FR), Bicêtre Hospital (FR)
Good health and well-being
Openalex Percentile: Top 11%
Antibiotic Resistance in Bacteria
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.