Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry

Charge detection mass spectrometry (CDMS) with electrostatic ion traps has been used to characterize the mass distributions of a variety of nanoparticles that have masses ranging from ∼1 to 400 megadaltons (MDa). Here, samples of polystyrene nanospheres from three different manufacturers with diameters ∼200 nm and masses of several gigadaltons (GDa) were characterized by both CDMS and transmission electron microscopy (TEM). From the centroid masses of ∼2.320, ∼2.602, and ∼2.897 GDa, centroid diameters of 191.4, 199.1, and 204.8 nm were obtained, respectively. These diameters are within 1% of those obtained from TEM measurements. The size distributions of the individual components in a mixture of these three samples were readily resolved with CDMS but not with TEM. The greater measurement time required for a statistically meaningful measurement from TEM led to some particle shrinkage that was not uniform between particles. The width of the most monodisperse nanoparticle sample distribution indicates that CDMS could distinguish two nanoparticle samples that differed by just 2 nm in diameter at this particle size (1%). The high resolution, minimal sample preparation requirements, compatibility with automation, and now extended mass range make CDMS a powerful high-throughput nanoparticle characterization tool for nanoparticles in biomedicine, advanced electronics, and material science.

Authors

Institutions

Publication Details

Journal
Small
Published
2026-06-12
DOI
https://doi.org/10.1002/smll.74148
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry

Evan R. Williams, Conner C. Harper, Veena S. Avadhani
Small
Mass Spectrometry Techniques and Applications
article

Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry

Evan R. Williams, Conner C. Harper, Veena S. Avadhani
article en

Abstract

Charge detection mass spectrometry (CDMS) with electrostatic ion traps has been used to characterize the mass distributions of a variety of nanoparticles that have masses ranging from ∼1 to 400 megadaltons (MDa). Here, samples of polystyrene nanospheres from three different manufacturers with diameters ∼200 nm and masses of several gigadaltons (GDa) were characterized by both CDMS and transmission electron microscopy (TEM). From the centroid masses of ∼2.320, ∼2.602, and ∼2.897 GDa, centroid diameters of 191.4, 199.1, and 204.8 nm were obtained, respectively. These diameters are within 1% of those obtained from TEM measurements. The size distributions of the individual components in a mixture of these three samples were readily resolved with CDMS but not with TEM. The greater measurement time required for a statistically meaningful measurement from TEM led to some particle shrinkage that was not uniform between particles. The width of the most monodisperse nanoparticle sample distribution indicates that CDMS could distinguish two nanoparticle samples that differed by just 2 nm in diameter at this particle size (1%). The high resolution, minimal sample preparation requirements, compatibility with automation, and now extended mass range make CDMS a powerful high-throughput nanoparticle characterization tool for nanoparticles in biomedicine, advanced electronics, and material science.

Small
University of California, Berkeley (US)
National Science Foundation, National Institutes of Health, Division of Chemistry
Openalex Percentile: Top 11%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry — Evan R. Williams, Conner C. Harper, et al. · Small (2026) | TGRS Research Map | TGRS