Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters

Flow diverters play an important role in the endovascular treatment of intracranial aneurysms; however, their use can be associated with thromboembolic complications. Thus, in recent years, flow diverters with surface coatings have been developed to prevent thrombus-related complications. In this study, the hemocompatibility of the flow diverters FRED X with poly(2-methoxyethyl acrylate) (PMEA) coating and the DERIVO 2heal with fibrin/heparin coating, as well as the uncoated DERIVO 2 flow diverter, was evaluated using an in vitro blood circulation model. Using enzyme-linked immunosorbent assay (ELISA), biomarkers of thrombocytes (β-thromboglobulin (β-TG)), coagulation (thrombin-antithrombin complex (TAT)), complement system (SC5b-9), and inflammation (PMN elastase) activation were analyzed. Further analyses comprised thrombogenicity assessment by scanning electron microscopy and measurement of blood cell counts and hemolysis. The uncoated DERIVO 2 flow diverter exhibited increased coagulation and platelet activation, accompanied by enhanced adhesion of platelets to the blood-contacting surfaces. In contrast, both the FRED X and the DERIVO 2-heal flow diverter could effectively reduce the coagulation (TAT) and platelet activation (β-TG) and prevent the adhesion of platelets. Notably, DERIVO 2heal flow diverter induced significantly lower activation of the complement system (SC5b-9) and reduced inflammatory response (PMN elastase) compared to FRED X flow diverter. These findings indicate the improved hemocompatibility of the fibrin/heparin-coated DERIVO 2heal flow diverter and its potential to reduce thromboinflammatory complications.

Authors

Institutions

Publication Details

Journal
Journal of Materials Science Materials in Medicine
Published
2026-06-13
DOI
https://doi.org/10.1007/s10856-026-07087-2
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters

Christian Schlensak, Meltem Avci‐Adali, Tomáš Riedel, Zuzana Riedelova et al.
Journal of Materials Science Materials in Medicine
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters

Christian Schlensak, Meltem Avci‐Adali, Tomáš Riedel, Zuzana Riedelova, Huan Wei, Melanie Wolf
article en

Abstract

Flow diverters play an important role in the endovascular treatment of intracranial aneurysms; however, their use can be associated with thromboembolic complications. Thus, in recent years, flow diverters with surface coatings have been developed to prevent thrombus-related complications. In this study, the hemocompatibility of the flow diverters FRED X with poly(2-methoxyethyl acrylate) (PMEA) coating and the DERIVO 2heal with fibrin/heparin coating, as well as the uncoated DERIVO 2 flow diverter, was evaluated using an in vitro blood circulation model. Using enzyme-linked immunosorbent assay (ELISA), biomarkers of thrombocytes (β-thromboglobulin (β-TG)), coagulation (thrombin-antithrombin complex (TAT)), complement system (SC5b-9), and inflammation (PMN elastase) activation were analyzed. Further analyses comprised thrombogenicity assessment by scanning electron microscopy and measurement of blood cell counts and hemolysis. The uncoated DERIVO 2 flow diverter exhibited increased coagulation and platelet activation, accompanied by enhanced adhesion of platelets to the blood-contacting surfaces. In contrast, both the FRED X and the DERIVO 2-heal flow diverter could effectively reduce the coagulation (TAT) and platelet activation (β-TG) and prevent the adhesion of platelets. Notably, DERIVO 2heal flow diverter induced significantly lower activation of the complement system (SC5b-9) and reduced inflammatory response (PMN elastase) compared to FRED X flow diverter. These findings indicate the improved hemocompatibility of the fibrin/heparin-coated DERIVO 2heal flow diverter and its potential to reduce thromboinflammatory complications.

Journal of Materials Science Materials in MedicineVol. 37(1)
Czech Academy of Sciences, Institute of Macromolecular Chemistry (CZ), University of Tübingen (DE)
Openalex Percentile: Top 6%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.