Snapshot Temporally Compressive Phase Imaging Based on Serial Modulation Multiplexing

ABSTRACT A phase‐imaging approach is proposed that allows retrieval of dozens of wavefields from a single diffraction frame. The approach is based on coherent modulation imaging (CMI), with an additional regularization constraint incorporated in its iterative algorithm. In a demonstration experiment, a total of 26 complex wavefields were retrieved from a single diffraction recording with quality similar to that of conventional CMI. It is shown that 50 wavefields were possible in simulations, corresponding to an oversampling ratio of 0.36. We also successfully employed this approach to measure the transient behavior of a spatial light modulator (SLM) at a temporal resolution of 2 ms using a 15 Hz frame‐rate detector. The method would be suitable for studying the dynamics of biological samples or energy materials using pulsed lasers, such as MHz free‐electron lasers, which have a much higher repetition rate than compatible area detectors.

Authors

Institutions

Publication Details

Journal
Laser & Photonics Review
Published
2026-06-12
DOI
https://doi.org/10.1002/lpor.71425
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Snapshot Temporally Compressive Phase Imaging Based on Serial Modulation Multiplexing

Yunshu Gao, Haitao Zhang, Fucai Zhang
Laser & Photonics Review
Advanced X-ray Imaging Techniques
article

Snapshot Temporally Compressive Phase Imaging Based on Serial Modulation Multiplexing

Yunshu Gao, Haitao Zhang, Fucai Zhang
article en

Abstract

ABSTRACT A phase‐imaging approach is proposed that allows retrieval of dozens of wavefields from a single diffraction frame. The approach is based on coherent modulation imaging (CMI), with an additional regularization constraint incorporated in its iterative algorithm. In a demonstration experiment, a total of 26 complex wavefields were retrieved from a single diffraction recording with quality similar to that of conventional CMI. It is shown that 50 wavefields were possible in simulations, corresponding to an oversampling ratio of 0.36. We also successfully employed this approach to measure the transient behavior of a spatial light modulator (SLM) at a temporal resolution of 2 ms using a 15 Hz frame‐rate detector. The method would be suitable for studying the dynamics of biological samples or energy materials using pulsed lasers, such as MHz free‐electron lasers, which have a much higher repetition rate than compatible area detectors.

Laser & Photonics Review
Southern University of Science and Technology (CN)
National Natural Science Foundation of China, Shenzhen Science and Technology Innovation Program
Affordable and clean energy
Openalex Percentile: Top 6%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.