FluoVolt Staining Compromises Cell Viability and Morphology during Live-Cell Voltage Imaging

Abstract Fluorescent voltage-sensitive dyes (VSDs) enable noninvasive, high-throughput optical monitoring of membrane potential in live cells but may introduce unintended experimental effects that complicate data interpretation. To address this, a key challenge is to characterize and minimize staining- and imaging-associated perturbations to optimize their reliable use across different cell types and imaging conditions. In this study, we systematically evaluate the VSD FluoVolt, its photobleaching, and its effects on cell viability, detachment, and morphology in cancer cell lines (GIN31 and SK-MEL-30) and primary human macrophages. Time-course imaging revealed cell-type-dependent photobleaching, with SK-MEL-30 cells exhibiting rapid fluorescence decay during imaging compared with other cell types. FluoVolt staining combined with excitation was associated with significant cell detachment in GIN31 and SK-MEL-30 cells and with reduced viability accompanied by pronounced morphological changes in GIN31 cells, characterized by a shift from an elongated to an amoeboid-like phenotype. Notably, morphological alterations were observed even in the absence of excitation, indicating that FluoVolt staining alone was also associated with measurable changes in cell morphology. Optimization of staining conditions using reduced dye and loading solution concentrations and incubation time significantly reduced these effects while maintaining measurable fluorescence. Collectively, these findings further characterize the effects associated with FluoVolt staining under the experimental conditions tested, highlight their dependence on cell type and imaging conditions, and emphasize the importance of protocol optimization for the reliable application of FluoVolt in live-cell imaging.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-11-13
DOI
https://doi.org/10.1021/acsomega.6c06843
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

FluoVolt Staining Compromises Cell Viability and Morphology during Live-Cell Voltage Imaging

Foteini Patera, Andrew Mark Jackson, Frankie James Rawson, Hester Franks et al.
ACS Omega
Advanced Fluorescence Microscopy Techniques
article

FluoVolt Staining Compromises Cell Viability and Morphology during Live-Cell Voltage Imaging

Foteini Patera, Andrew Mark Jackson, Frankie James Rawson, Hester Franks, Anna A. Malecka, Judith M. Ramage, Ruman Rahman, Adam Mark Blanchard, Ian Spendlove, Evren M. Akyuz, Fleur E Groualle, Stuart J. Smith, Manuela Mitroi
article en

Abstract

Abstract Fluorescent voltage-sensitive dyes (VSDs) enable noninvasive, high-throughput optical monitoring of membrane potential in live cells but may introduce unintended experimental effects that complicate data interpretation. To address this, a key challenge is to characterize and minimize staining- and imaging-associated perturbations to optimize their reliable use across different cell types and imaging conditions. In this study, we systematically evaluate the VSD FluoVolt, its photobleaching, and its effects on cell viability, detachment, and morphology in cancer cell lines (GIN31 and SK-MEL-30) and primary human macrophages. Time-course imaging revealed cell-type-dependent photobleaching, with SK-MEL-30 cells exhibiting rapid fluorescence decay during imaging compared with other cell types. FluoVolt staining combined with excitation was associated with significant cell detachment in GIN31 and SK-MEL-30 cells and with reduced viability accompanied by pronounced morphological changes in GIN31 cells, characterized by a shift from an elongated to an amoeboid-like phenotype. Notably, morphological alterations were observed even in the absence of excitation, indicating that FluoVolt staining alone was also associated with measurable changes in cell morphology. Optimization of staining conditions using reduced dye and loading solution concentrations and incubation time significantly reduced these effects while maintaining measurable fluorescence. Collectively, these findings further characterize the effects associated with FluoVolt staining under the experimental conditions tested, highlight their dependence on cell type and imaging conditions, and emphasize the importance of protocol optimization for the reliable application of FluoVolt in live-cell imaging.

ACS Omega
Nottingham University Hospitals NHS Trust (GB), University of Nottingham (GB), University of Lincoln (GB)
University of Nottingham, Engineering and Physical Sciences Research Council
Good health and well-being
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon