Spine-pelvis-hip biomechanics of PLIF, TLIF, and LLIF at L4-5: a finite element study in Roussouly type II alignment

Lumbar interbody fusion at L4-5 is commonly performed for degenerative lumbar disorders. Patients with Roussouly type II sagittal alignment typically have a relatively flat lumbar profile, which may alter lower lumbar load transfer and postoperative mechanical behavior. Most finite element studies of lumbar fusion have focused on the lumbar spine alone, whereas the pelvis and hip joints are rarely included as part of the load-transfer pathway. A three-dimensional finite element model of the lumbar spine, pelvis, and bilateral proximal femora was derived from CT data of a healthy adult male volunteer with Roussouly type II alignment. PLIF, TLIF, and LLIF constructs at L4-5 were simulated with bilateral pedicle screw fixation. Under six physiological loading conditions, von Mises stress distributions were evaluated in the adjacent L3-4 intervertebral disc, the L5 superior endplate, the pedicle screw-rod system, and acetabular cartilage. All three constructs provided immediate stabilization at the operated segment. Peak L3-4 nucleus pulposus stress showed only minor differences among constructs, whereas stress distribution varied during lateral bending and axial rotation. TLIF produced the highest stress concentration in the posterior fixation system, particularly during lateral bending and axial rotation. Endplate stress was more concentrated in the posterior constructs, while LLIF showed reduced stress under the present model. Acetabular cartilage stress showed differences in spatial distribution among constructs under the simplified hip boundary conditions. In a Roussouly type II finite element model, PLIF, TLIF, and LLIF achieved comparable immediate stabilization at L4-5 but differed in load-sharing behavior. LLIF reduced mechanical demand on posterior instrumentation and produced more homogeneous endplate loading, while TLIF showed greater posterior implant stress concentration. These findings provide comparative biomechanical insights into construct-specific behavior within a Roussouly type II alignment framework.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-11-16
DOI
https://doi.org/10.1186/s12891-026-10467-y
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Spine-pelvis-hip biomechanics of PLIF, TLIF, and LLIF at L4-5: a finite element study in Roussouly type II alignment

Xingze Zhang, Jun Miao, C Y Chen, Qiang Yang et al.
1 links
BMC Musculoskeletal Disorders
Spine and Intervertebral Disc Pathology
article

Spine-pelvis-hip biomechanics of PLIF, TLIF, and LLIF at L4-5: a finite element study in Roussouly type II alignment

Xingze Zhang, Jun Miao, C Y Chen, Qiang Yang, Haochen Hu, Yonggui Wu
article en

Abstract

Lumbar interbody fusion at L4-5 is commonly performed for degenerative lumbar disorders. Patients with Roussouly type II sagittal alignment typically have a relatively flat lumbar profile, which may alter lower lumbar load transfer and postoperative mechanical behavior. Most finite element studies of lumbar fusion have focused on the lumbar spine alone, whereas the pelvis and hip joints are rarely included as part of the load-transfer pathway. A three-dimensional finite element model of the lumbar spine, pelvis, and bilateral proximal femora was derived from CT data of a healthy adult male volunteer with Roussouly type II alignment. PLIF, TLIF, and LLIF constructs at L4-5 were simulated with bilateral pedicle screw fixation. Under six physiological loading conditions, von Mises stress distributions were evaluated in the adjacent L3-4 intervertebral disc, the L5 superior endplate, the pedicle screw-rod system, and acetabular cartilage. All three constructs provided immediate stabilization at the operated segment. Peak L3-4 nucleus pulposus stress showed only minor differences among constructs, whereas stress distribution varied during lateral bending and axial rotation. TLIF produced the highest stress concentration in the posterior fixation system, particularly during lateral bending and axial rotation. Endplate stress was more concentrated in the posterior constructs, while LLIF showed reduced stress under the present model. Acetabular cartilage stress showed differences in spatial distribution among constructs under the simplified hip boundary conditions. In a Roussouly type II finite element model, PLIF, TLIF, and LLIF achieved comparable immediate stabilization at L4-5 but differed in load-sharing behavior. LLIF reduced mechanical demand on posterior instrumentation and produced more homogeneous endplate loading, while TLIF showed greater posterior implant stress concentration. These findings provide comparative biomechanical insights into construct-specific behavior within a Roussouly type II alignment framework.

BMC Musculoskeletal Disorders
Tianjin University (CN), Capital Medical University (CN), Tianjin Hospital (CN), Beijing Friendship Hospital (CN), Tianjin Medical University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia
Good health and well-being
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon