Impact of cardiac phase selection on the diagnostic performance of CT-FFR: the role of myocardial bridging and heart rate

Computed tomography-derived fractional flow reserve (CT-FFR) is commonly calculated from diastolic-phase coronary CT angiography, but phase selection may be affected by high heart rate and myocardial bridging. We compared CT-FFR derived from systolic- and diastolic-phase reconstructions and explored phase-related differences according to myocardial bridging and heart rate. This retrospective, single-center diagnostic-accuracy study included 138 patients contributing 155 vessels examined using a second-generation single-source 320-detector-row CT platform. CT-FFR was calculated separately from diastolic- and systolic-phase reconstructions using the same steady-state computational framework. Invasive FFR and CT-FFR values ≤ 0.80 were considered positive. Analyses of the invasive-FFR-defined grey zone (0.75–0.85), myocardial bridging, heart-rate groups (≤ 70 vs. > 70 beats/min), and subgroup interactions were post hoc and exploratory. Diastolic-reconstruction-derived CT-FFR showed higher overall discrimination than systolic-reconstruction-derived CT-FFR (AUC, 0.91 vs. 0.87; difference, 0.039; patient-clustered bootstrap 95% CI, 0.006–0.072). Diagnostic correctness did not differ significantly after accounting for within-patient clustering (OR, 1.18; 95% CI, 0.84–1.67; P = 0.346). In the invasive-FFR-defined grey zone, paired accuracy was 78.4% versus 56.9% (difference, 21.6% points; 95% CI, 4.5–37.0; exact McNemar P = 0.027). In vessels with myocardial bridging, the observed AUC was higher for diastolic than systolic reconstruction (0.90 vs. 0.79; P = 0.011), with an exploratory phase-by-myocardial-bridging interaction (OR, 2.72; 95% CI, 1.07–6.92; P = 0.036). In the heart-rate > 70 beats/min subgroup, no significant phase difference or phase-by-heart-rate interaction was detected. Diastolic-phase reconstruction showed slightly higher overall discrimination, whereas threshold-based diagnostic correctness was similar after accounting for clustering. Myocardial bridging may modify phase-related performance, but heart-rate-stratified findings remain hypothesis-generating.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-11-17
DOI
https://doi.org/10.1186/s12880-026-02716-2
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Impact of cardiac phase selection on the diagnostic performance of CT-FFR: the role of myocardial bridging and heart rate

J Y Ma, Rende Xu, Jie Zhou, Jianhui Song et al.
2 links
BMC Medical Imaging
Cardiac Imaging and Diagnostics
article

Impact of cardiac phase selection on the diagnostic performance of CT-FFR: the role of myocardial bridging and heart rate

J Y Ma, Rende Xu, Jie Zhou, Jianhui Song, WEI GAO, QIYU ZHANG, CHENGUANG LI, LEILEI MA, JUYING QIAN, YAN XIA, FANG ZHANG, JUNBO GE
article en

Abstract

Computed tomography-derived fractional flow reserve (CT-FFR) is commonly calculated from diastolic-phase coronary CT angiography, but phase selection may be affected by high heart rate and myocardial bridging. We compared CT-FFR derived from systolic- and diastolic-phase reconstructions and explored phase-related differences according to myocardial bridging and heart rate. This retrospective, single-center diagnostic-accuracy study included 138 patients contributing 155 vessels examined using a second-generation single-source 320-detector-row CT platform. CT-FFR was calculated separately from diastolic- and systolic-phase reconstructions using the same steady-state computational framework. Invasive FFR and CT-FFR values ≤ 0.80 were considered positive. Analyses of the invasive-FFR-defined grey zone (0.75–0.85), myocardial bridging, heart-rate groups (≤ 70 vs. > 70 beats/min), and subgroup interactions were post hoc and exploratory. Diastolic-reconstruction-derived CT-FFR showed higher overall discrimination than systolic-reconstruction-derived CT-FFR (AUC, 0.91 vs. 0.87; difference, 0.039; patient-clustered bootstrap 95% CI, 0.006–0.072). Diagnostic correctness did not differ significantly after accounting for within-patient clustering (OR, 1.18; 95% CI, 0.84–1.67; P = 0.346). In the invasive-FFR-defined grey zone, paired accuracy was 78.4% versus 56.9% (difference, 21.6% points; 95% CI, 4.5–37.0; exact McNemar P = 0.027). In vessels with myocardial bridging, the observed AUC was higher for diastolic than systolic reconstruction (0.90 vs. 0.79; P = 0.011), with an exploratory phase-by-myocardial-bridging interaction (OR, 2.72; 95% CI, 1.07–6.92; P = 0.036). In the heart-rate > 70 beats/min subgroup, no significant phase difference or phase-by-heart-rate interaction was detected. Diastolic-phase reconstruction showed slightly higher overall discrimination, whereas threshold-based diagnostic correctness was similar after accounting for clustering. Myocardial bridging may modify phase-related performance, but heart-rate-stratified findings remain hypothesis-generating.

BMC Medical Imaging
University of Shanghai for Science and Technology (CN), Fudan University (CN), Zhongshan Hospital (CN)
National Natural Science Foundation of China, Fudan University, Shanghai Hospital Development Center
Good health and well-being
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon