Retention behavior and surface alterations of ball and TRI raptor unsplinted overdenture attachments after thermomechanical aging: an in vitro study

Abstract Background To compare the time-dependent retentive-force behavior and wear-related surface alterations of two unsplinted overdenture attachment systems, a ball attachment system and a TRI Raptor Smart Box system, after standardized thermomechanical aging. Methods In this in vitro study, a ball attachment system (clear and gray matrix inserts) and a TRI Raptor Smart Box system (purple, clear and pink inserts) were evaluated (n = 10 per subgroup). Custom specimen holders were fabricated to simulate attachment–matrix engagement. Artificial aging was performed in a thermocycling chewing simulator between 5°C and 55°C with simultaneous cyclic loading. Retentive-force measurements were obtained after 120, 720, 1440 and 2160 cycles, corresponding approximately to 1, 6, 12 and 18 months of clinical use. Pull-off force was measured using a microtensile testing device. Representative components were examined by scanning electron microscopy after the final aging interval. Results Retentive force decreased significantly over time in all subgroups. In the ball attachment system, the gray insert consistently showed higher retentive-force values than the clear insert. In the TRI Raptor Smart Box system, the purple insert showed the highest retentive-force values at 1, 6 and 18 months, with a transient crossover at 12 months, when the clear insert showed the highest mean value. The pink Raptor insert showed the lowest values overall. SEM demonstrated subgroup-specific wear-related surface alterations after cyclic aging. Conclusions Retentive-force loss was not uniform across the tested unsplinted overdenture attachment subgroups. Insert-specific material and design characteristics influenced retention behavior and may be relevant to attachment selection and maintenance planning in implant overdenture therapy.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-09-05
DOI
https://doi.org/10.1186/s12903-026-09827-w
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Retention behavior and surface alterations of ball and TRI raptor unsplinted overdenture attachments after thermomechanical aging: an in vitro study

Huseyin Kurtulmus, Egemen Sezen
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Retention behavior and surface alterations of ball and TRI raptor unsplinted overdenture attachments after thermomechanical aging: an in vitro study

Huseyin Kurtulmus, Egemen Sezen
article en

Abstract

Abstract Background To compare the time-dependent retentive-force behavior and wear-related surface alterations of two unsplinted overdenture attachment systems, a ball attachment system and a TRI Raptor Smart Box system, after standardized thermomechanical aging. Methods In this in vitro study, a ball attachment system (clear and gray matrix inserts) and a TRI Raptor Smart Box system (purple, clear and pink inserts) were evaluated (n = 10 per subgroup). Custom specimen holders were fabricated to simulate attachment–matrix engagement. Artificial aging was performed in a thermocycling chewing simulator between 5°C and 55°C with simultaneous cyclic loading. Retentive-force measurements were obtained after 120, 720, 1440 and 2160 cycles, corresponding approximately to 1, 6, 12 and 18 months of clinical use. Pull-off force was measured using a microtensile testing device. Representative components were examined by scanning electron microscopy after the final aging interval. Results Retentive force decreased significantly over time in all subgroups. In the ball attachment system, the gray insert consistently showed higher retentive-force values than the clear insert. In the TRI Raptor Smart Box system, the purple insert showed the highest retentive-force values at 1, 6 and 18 months, with a transient crossover at 12 months, when the clear insert showed the highest mean value. The pink Raptor insert showed the lowest values overall. SEM demonstrated subgroup-specific wear-related surface alterations after cyclic aging. Conclusions Retentive-force loss was not uniform across the tested unsplinted overdenture attachment subgroups. Insert-specific material and design characteristics influenced retention behavior and may be relevant to attachment selection and maintenance planning in implant overdenture therapy.

BMC Oral Health
Izmir University (TR), İzmir University of Economics (TR), Istanbul Yeni Yüzyıl University (TR)
Erciyes Üniversitesi
Openalex Percentile: Top 47%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.