Femoral neck anteversion- what’s normal in Indians: a morphological study of 742 hips using CT-based MAKO robotic evaluation

BACKGROUND: Femoral neck anteversion (FNA) is a key determinant of hip biomechanics and component positioning in total hip arthroplasty (THA). Most reference values for femoral version are derived from Western populations and non-robotic measurement techniques. Data defining native femoral version in the Indian population using CT-based robotic planning are limited. METHODS: This multicenter cross-sectional study analyzed 742 hips undergoing primary robotic-assisted THA using the MAKO THA 4.0 system. Native femoral version was calculated automatically from preoperative CT scans as the angle between the femoral neck axis and the trans-epicondylar axis. Femoral version was categorized as retroversion (< 0°), neutral (0°), or anteversion (> 0°). Descriptive statistics were reported as Mean (SD). Group comparisons were performed using chi-square tests, with statistical significance set at p < 0.05. RESULTS: The mean native femoral version was - 2.6° (SD 11.9), with a range from - 42° to 41°. Overall, 395 hips (53.2%) demonstrated retroversion, 320 hips (43.1%) anteversion, and 27 hips (3.6%) neutral alignment. Retroversion predominated in males, whereas females showed significantly higher anteversion (p < 0.001). No statistically significant differences were observed across age groups (p = 0.310; Spearman ρ = 0.034, p = 0.356) or diagnosis categories (p = 0.227). Notably, 703 hips (94.7%) demonstrated femoral version below 15°. CONCLUSION: Indian patients undergoing THA demonstrate substantially lower femoral neck anteversion than commonly cited Western norms, with more than half exhibiting femoral retroversion. These findings highlight the importance of population-specific and individualized preoperative planning, for which CT-based assessment can be useful.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-06-09
DOI
https://doi.org/10.1186/s12891-026-10041-6
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Femoral neck anteversion- what’s normal in Indians: a morphological study of 742 hips using CT-based MAKO robotic evaluation

Adarsh Annapareddy, Vemaganti Badri Narayana Prasad, Mahesh Kulkarni, Ravikumar Mukartihal et al.
BMC Musculoskeletal Disorders
Orthopaedic implants and arthroplasty
article

Femoral neck anteversion- what’s normal in Indians: a morphological study of 742 hips using CT-based MAKO robotic evaluation

Adarsh Annapareddy, Vemaganti Badri Narayana Prasad, Mahesh Kulkarni, Ravikumar Mukartihal, Mujtaba Ansari, A V Gurava Reddy, Rohit Rakesh Luthra, Sharan S. Patil, Arun Kannan, Sneh Shah, Ashish Singh, Tarun Jayakumar
article en

Abstract

BACKGROUND: Femoral neck anteversion (FNA) is a key determinant of hip biomechanics and component positioning in total hip arthroplasty (THA). Most reference values for femoral version are derived from Western populations and non-robotic measurement techniques. Data defining native femoral version in the Indian population using CT-based robotic planning are limited. METHODS: This multicenter cross-sectional study analyzed 742 hips undergoing primary robotic-assisted THA using the MAKO THA 4.0 system. Native femoral version was calculated automatically from preoperative CT scans as the angle between the femoral neck axis and the trans-epicondylar axis. Femoral version was categorized as retroversion (< 0°), neutral (0°), or anteversion (> 0°). Descriptive statistics were reported as Mean (SD). Group comparisons were performed using chi-square tests, with statistical significance set at p < 0.05. RESULTS: The mean native femoral version was - 2.6° (SD 11.9), with a range from - 42° to 41°. Overall, 395 hips (53.2%) demonstrated retroversion, 320 hips (43.1%) anteversion, and 27 hips (3.6%) neutral alignment. Retroversion predominated in males, whereas females showed significantly higher anteversion (p < 0.001). No statistically significant differences were observed across age groups (p = 0.310; Spearman ρ = 0.034, p = 0.356) or diagnosis categories (p = 0.227). Notably, 703 hips (94.7%) demonstrated femoral version below 15°. CONCLUSION: Indian patients undergoing THA demonstrate substantially lower femoral neck anteversion than commonly cited Western norms, with more than half exhibiting femoral retroversion. These findings highlight the importance of population-specific and individualized preoperative planning, for which CT-based assessment can be useful.

BMC Musculoskeletal Disorders
National Institute of Technology Patna (IN), ACE Hospital (IN), Sunshine Hospitals (IN), Sparsh Hospital (IN), Deenanath Mangeshkar Hospital and Research Center (IN), Apollo Hospitals (IN), Apollo Hospitals (IN)
Openalex Percentile: Top 5%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.