Native Mass Spectrometry of Soluble Proteins with Sodium Chloride Enabled by a Dendritic Detergent

High Resolution Image Download MS PowerPoint Slide Salts are essential for maintaining native protein structure and biomolecular interactions. Native mass spectrometry often yields uninterpretable spectra due to salt adduction and signal suppression. Existing workarounds require buffer exchange or extensive cleanup, which can disrupt weak noncovalent interactions and reduce throughput. Addressing this shortcoming, we establish a first-generation, dendritic triglycerol detergent as a simple-to-apply additive that enables native mass spectrometry of biophysically relevant protein concentrations in the presence of sodium chloride. Adding this detergent to sodium chloride–containing samples prior to electrospray ionization improves spectral quality, enhances signal-to-noise ratios, and enables an acquisition of interpretable native mass spectrometry data for soluble proteins, including complexes with lipids and drugs, at different ionic strengths. These improvements are achieved without compromising native-like charge-state distributions across proteins ranging from myoglobin and lipopolysaccharide transport protein H to bovine serum albumin and high-mass tetramers, such as alcohol dehydrogenase and pyruvate kinase. Nuclear magnetic resonance data indicate a concentration-dependent sodium chloride complexation by detergent in solution, consistent with desalted protein complexes observable in the gas phase. By rendering sodium chloride compatible with native mass spectrometry, first-generation, dendritic triglycerol detergent enables the routine analysis of protein complexes at otherwise inaccessible ionic strengths and biophysically relevant analyte concentrations.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2026-06-09
DOI
https://doi.org/10.1021/acsmeasuresciau.6c00038
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Native Mass Spectrometry of Soluble Proteins with Sodium Chloride Enabled by a Dendritic Detergent

Leonhard Hagen Urner, Wolf Hiller, Francesco Fiorentino
ACS Measurement Science Au
Mass Spectrometry Techniques and Applications
article

Native Mass Spectrometry of Soluble Proteins with Sodium Chloride Enabled by a Dendritic Detergent

Leonhard Hagen Urner, Wolf Hiller, Francesco Fiorentino
article en

Abstract

High Resolution Image Download MS PowerPoint Slide Salts are essential for maintaining native protein structure and biomolecular interactions. Native mass spectrometry often yields uninterpretable spectra due to salt adduction and signal suppression. Existing workarounds require buffer exchange or extensive cleanup, which can disrupt weak noncovalent interactions and reduce throughput. Addressing this shortcoming, we establish a first-generation, dendritic triglycerol detergent as a simple-to-apply additive that enables native mass spectrometry of biophysically relevant protein concentrations in the presence of sodium chloride. Adding this detergent to sodium chloride–containing samples prior to electrospray ionization improves spectral quality, enhances signal-to-noise ratios, and enables an acquisition of interpretable native mass spectrometry data for soluble proteins, including complexes with lipids and drugs, at different ionic strengths. These improvements are achieved without compromising native-like charge-state distributions across proteins ranging from myoglobin and lipopolysaccharide transport protein H to bovine serum albumin and high-mass tetramers, such as alcohol dehydrogenase and pyruvate kinase. Nuclear magnetic resonance data indicate a concentration-dependent sodium chloride complexation by detergent in solution, consistent with desalted protein complexes observable in the gas phase. By rendering sodium chloride compatible with native mass spectrometry, first-generation, dendritic triglycerol detergent enables the routine analysis of protein complexes at otherwise inaccessible ionic strengths and biophysically relevant analyte concentrations.

ACS Measurement Science Au
TU Dortmund University (DE), Sapienza University of Rome (IT)
Fonds der Chemischen Industrie, Ministerium für Kultur und Wissenschaft des Landes Nordrhein-Westfalen, HORIZON EUROPE Marie Sklodowska-Curie Actions
Industry, innovation and infrastructure
Openalex Percentile: Top 11%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.