Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study

BACKGROUND: Optic nerve sheath diameter (ONSD) is a widely used non-invasive surrogate marker of intracranial pressure. Current recommendations state that measurements should be obtained with a neutral gaze. However, the effect of gaze deviation on ONSD has never been investigated. We aimed to evaluate the reliability of ONSD in case of gaze deviation and quantify the associated measurement error. A secondary aim was to assess whether bed inclination has a significant effect on ONSD values. METHODS: We conducted a prospective interventional study on 44 healthy volunteers during routine ocular ultrasound training. ONSD was measured bilaterally along the horizontal and vertical axes at 45° head-of-bed elevation in neutral and deviated gaze. After repositioning the bed to 0° and a 2-minute stabilization period, horizontal measurements were repeated. Measurements were performed according to current consensus recommendations and ALARA principles. Nonparametric analyses were used to analyse the results. RESULTS: Gaze deviation significantly reduced ONSD values across all axes and both eyes, with a consistent median difference of 0.8-1.0 mm (all p < 0.001) and large effect sizes. In contrast, no significant differences were observed between measurements obtained at 45° and 0° (p > 0.5). CONCLUSIONS: Gaze deviation induces a predictable "stretching" effect on the optic nerve sheath, resulting in clinically relevant ONSD reduction. If confirmed in neurocritical populations, this systematic difference may allow estimation of neutral-gaze ONSD in non compliant patients and could form the basis for a dynamic test that estimates optic nerve sheath compliance.

Authors

Institutions

Publication Details

Journal
The Ultrasound Journal
Published
2026-06-09
DOI
https://doi.org/10.5826/tuj.2026.18767
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study

Francesco Corradi, Francesco Forfori, Giulio Costanzo, Giada Cucciolini et al.
The Ultrasound Journal
Traumatic Brain Injury and Neurovascular Disturbances
article

Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study

Francesco Corradi, Francesco Forfori, Giulio Costanzo, Giada Cucciolini, Francesco Masi, Gaia Mignani
article en

Abstract

BACKGROUND: Optic nerve sheath diameter (ONSD) is a widely used non-invasive surrogate marker of intracranial pressure. Current recommendations state that measurements should be obtained with a neutral gaze. However, the effect of gaze deviation on ONSD has never been investigated. We aimed to evaluate the reliability of ONSD in case of gaze deviation and quantify the associated measurement error. A secondary aim was to assess whether bed inclination has a significant effect on ONSD values. METHODS: We conducted a prospective interventional study on 44 healthy volunteers during routine ocular ultrasound training. ONSD was measured bilaterally along the horizontal and vertical axes at 45° head-of-bed elevation in neutral and deviated gaze. After repositioning the bed to 0° and a 2-minute stabilization period, horizontal measurements were repeated. Measurements were performed according to current consensus recommendations and ALARA principles. Nonparametric analyses were used to analyse the results. RESULTS: Gaze deviation significantly reduced ONSD values across all axes and both eyes, with a consistent median difference of 0.8-1.0 mm (all p < 0.001) and large effect sizes. In contrast, no significant differences were observed between measurements obtained at 45° and 0° (p > 0.5). CONCLUSIONS: Gaze deviation induces a predictable "stretching" effect on the optic nerve sheath, resulting in clinically relevant ONSD reduction. If confirmed in neurocritical populations, this systematic difference may allow estimation of neutral-gaze ONSD in non compliant patients and could form the basis for a dynamic test that estimates optic nerve sheath compliance.

The Ultrasound JournalVol. 18(1)
University of Pisa (IT), NATO Centre for Maritime Research and Experimentation (IT)
Openalex Percentile: Top 9%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.