Stable Lord Madreporic Femoral Stem 32 Years After Revision Total Hip Arthroplasty: A Case Report

The Lord total hip prosthesis was discontinued because of high rates of failure of the threaded acetabular component and marked proximal femoral bone atrophy related to stress shielding. We report an exceptionally long-term follow-up of a Lord femoral stem that remains stable 32 years after implantation. In 1994, a 37-year-old tailor underwent left revision total hip arthroplasty (THA) using the Lord system. Fifteen years later, in 2009, he presented in our orthopedic department with pain and substantial functional impairment. Imaging demonstrated aseptic loosening of the Lord acetabular cup with massive bone loss, and revision arthroplasty was performed. Periprosthetic bone loss was reconstructed with 120 cc of impacted cryopreserved morselized cancellous allograft, followed by implantation of a Burch-Schneider (Zimmer Biomet, IN, USA) anti-protrusio cage. The Lord femoral stem showed excellent osseointegration and mechanical stability and was therefore retained. An attempt to exchange the femoral head was unsuccessful due to cold welding at the Morse taper. In 2014, five years after the Lord acetabular revision, radiographs demonstrated fracture of the distal flange of the acetabular cage with lateralization of the implant. However, the patient remained asymptomatic and maintained satisfactory joint function, using a 2 cm shoe lift and a cane. A conservative watchful-waiting strategy was adopted. In 2026, at the 32-year follow-up, the Lord femoral stem continued to demonstrate clinical and radiographic stability, with no subsidence or progressive radiolucent lines besides secondary acetabular reconstruction challenges. To our knowledge, this represents one of the longest documented follow-up periods for a stable Lord femoral stem in the literature.

Authors

Publication Details

Journal
Cureus
Published
2026-06-09
DOI
https://doi.org/10.7759/cureus.110531
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stable Lord Madreporic Femoral Stem 32 Years After Revision Total Hip Arthroplasty: A Case Report

António Mendonça, Fernando Judas, José Rodrigues, Pedro Farinha et al.
Cureus
Orthopaedic implants and arthroplasty
article

Stable Lord Madreporic Femoral Stem 32 Years After Revision Total Hip Arthroplasty: A Case Report

António Mendonça, Fernando Judas, José Rodrigues, Pedro Farinha, João C Mendes, Daniela Isidoro, João Bessa, Maria Parreira
article en

Abstract

The Lord total hip prosthesis was discontinued because of high rates of failure of the threaded acetabular component and marked proximal femoral bone atrophy related to stress shielding. We report an exceptionally long-term follow-up of a Lord femoral stem that remains stable 32 years after implantation. In 1994, a 37-year-old tailor underwent left revision total hip arthroplasty (THA) using the Lord system. Fifteen years later, in 2009, he presented in our orthopedic department with pain and substantial functional impairment. Imaging demonstrated aseptic loosening of the Lord acetabular cup with massive bone loss, and revision arthroplasty was performed. Periprosthetic bone loss was reconstructed with 120 cc of impacted cryopreserved morselized cancellous allograft, followed by implantation of a Burch-Schneider (Zimmer Biomet, IN, USA) anti-protrusio cage. The Lord femoral stem showed excellent osseointegration and mechanical stability and was therefore retained. An attempt to exchange the femoral head was unsuccessful due to cold welding at the Morse taper. In 2014, five years after the Lord acetabular revision, radiographs demonstrated fracture of the distal flange of the acetabular cage with lateralization of the implant. However, the patient remained asymptomatic and maintained satisfactory joint function, using a 2 cm shoe lift and a cane. A conservative watchful-waiting strategy was adopted. In 2026, at the 32-year follow-up, the Lord femoral stem continued to demonstrate clinical and radiographic stability, with no subsidence or progressive radiolucent lines besides secondary acetabular reconstruction challenges. To our knowledge, this represents one of the longest documented follow-up periods for a stable Lord femoral stem in the literature.

Cureus
Openalex Percentile: Top 6%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stable Lord Madreporic Femoral Stem 32 Years After Revision Total Hip Arthroplasty: A Case Report — António Mendonça, Fernando Judas, et al. · Cureus (2026) | TGRS Research Map | TGRS